Search icon

4M CONSTRUCTION INC

Company Details

Name: 4M CONSTRUCTION INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 19 Mar 2014 (11 years ago)
Entity Number: 4546862
ZIP code: 11218
County: Kings
Place of Formation: New York
Address: 363 OCEAN PARKWAY APT A-7, BROOKLYN, NY, United States, 11218

Contact Details

Phone +1 718-693-0979

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 363 OCEAN PARKWAY APT A-7, BROOKLYN, NY, United States, 11218

Licenses

Number Status Type Date End date
2021769-DCA Inactive Business 2015-04-28 2019-02-28

Filings

Filing Number Date Filed Type Effective Date
140319010090 2014-03-19 CERTIFICATE OF INCORPORATION 2014-03-19

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2016-09-06 No data PACIFIC STREET, FROM STREET BOND STREET TO STREET HOYT STREET No data Street Construction Inspections: Post-Audit Department of Transportation r\w mill for pave
2015-11-02 No data PACIFIC STREET, FROM STREET BOND STREET TO STREET HOYT STREET No data Street Construction Inspections: Post-Audit Department of Transportation cobblestone sidewalk repaired.

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
2482070 TRUSTFUNDHIC INVOICED 2016-11-02 200 Home Improvement Contractor Trust Fund Enrollment Fee
2482071 RENEWAL INVOICED 2016-11-02 100 Home Improvement Contractor License Renewal Fee
2060590 LICENSE INVOICED 2015-04-28 100 Home Improvement Contractor License Fee
2060594 FINGERPRINT CREDITED 2015-04-28 75 Fingerprint Fee
2060591 TRUSTFUNDHIC INVOICED 2015-04-28 200 Home Improvement Contractor Trust Fund Enrollment Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343718961 0215000 2019-01-16 231 AINSLIE STREET, BROOKLYN, NY, 11211
Inspection Type FollowUp
Scope NoInspection
Safety/Health Safety
Close Conference 2019-01-16
Case Closed 2019-01-23

Related Activity

Type Inspection
Activity Nr 1307914
Safety Yes
343079141 0215000 2018-04-09 231 AINSLIE STREET, BROOKLYN, NY, 11211
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-04-09
Emphasis L: FALL
Case Closed 2023-01-19

Related Activity

Type Referral
Activity Nr 1327038
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2018-06-22
Abatement Due Date 2018-06-28
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-07-31
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Location: a) Supported scaffold on the southeast side of the job site: On or about 04/09/18, employees were working on a 5-tier-high supported scaffold. The scaffold platform was not fully planked or decked between the front uprights and the guardrail supports.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2018-06-22
Abatement Due Date 2018-06-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-07-31
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide. Location: a) Supported scaffold on the southeast side of the job site: On or about 04/09/18, employees were working on a 5-tier-high supported scaffold. The scaffold platform was not at least 18 inches wide.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G04 IV
Issuance Date 2018-06-22
Abatement Due Date 2018-06-28
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2018-07-31
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface. Location: a) Supported scaffold on the southeast side of the job site: On or about 04/09/18, employees were working on a 5-tier-high supported scaffold. On the working platform, midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2018-06-22
Abatement Due Date 2018-07-05
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2018-07-31
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Location: a) Supported scaffold on the southeast side of the job site On or about 04/09/18, employer did not have employees who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2018-06-22
Abatement Due Date 2018-06-28
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2018-07-31
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided. Location: a) On the first floor of the jobsite: On or about 04/09/18, employees used the top step of an 6 feet A-frame ladder to climb to the top of the sidewalk shed. The top of the sidewalk shed was approximately 3 feet above the top of the ladder. b) On the first floor of the jobsite: On or about 04/09/18, employees access the top of the sidewalk shed from an extension ladder. The extension ladder entrance is approximately 3 feet above the top of the sidewalk shed.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2018-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-07-31
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step. Location: a) On the first floor of the jobsite: On or about 04/09/18, employees used the top step of an 6 feet A-frame ladder to climb to the top of the sidewalk shed. The top of the sidewalk shed was approximately 3 feet above the top of the ladder.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2018-06-22
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2018-07-31
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed; the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. Location: a) On the first floor of the jobsite: On or about 04/09/18, employees access the top of the sidewalk shed from an extension ladder. The extension ladder is not extend at least 3 feet above the upper landing surface being accessed or not secured at its top to a rigid support or was not provided a grasping device.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19261053 B07
Issuance Date 2018-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-07-31
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(7): Ladder(s) that were unsecured or not provided with slip-resistant feet were used on slippery surfaces. Location: a) On the first floor of the jobsite: On or about 04/09/18, employees access the top of the sidewalk shed from an extension ladder. The ladder was unsecured or not provided with slip-resistant feet.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2018-06-22
Abatement Due Date 2018-07-05
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2018-07-31
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways. Location: a) On the first floor of the jobsite: On or about 04/09/18, employer did not provide training to each employee who used ladders for access to the sidewalk shed that were exposed to a fall hazard to enable each employee to recognize the hazards related to ladders and the procedure to be followed in order to minimize these hazards.