Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-10-20
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-05-30
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2017-12-12 |
Current Penalty |
2077.5 |
Initial Penalty |
2770.0 |
Final Order |
2018-01-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 10/20/17, at the residence complex 1186 - 1200 of the Webster Green apartments, located in Webster, New York, employees working on a steep roof, were not protected from falling 20 feet to ground level with fall protection. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2017-12-12 |
Current Penalty |
1385.25 |
Initial Penalty |
1847.0 |
Final Order |
2018-01-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed a) On or about 10/20/17, at residence complex 1186 - 1200 of the Webster Green apartments, located in Webster, New York, a portable extension ladder was in use to access a residential roof 20 feet above ground level, during the installation of roofing shingles and did not extend 3 feet above the landing. NO ABATEMENT CERTIFICATION REQUIRED |
|
|