Search icon

HY DESIGN & DEVELOPMENT LLC

Company Details

Name: HY DESIGN & DEVELOPMENT LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 23 Apr 2014 (11 years ago)
Entity Number: 4565825
ZIP code: 11358
County: Queens
Place of Formation: New York
Address: 47-27 195TH ST., FLUSHING, NY, United States, 11358

Contact Details

Phone +1 646-644-3567

DOS Process Agent

Name Role Address
HY DESIGN & DEVELOPMENT LLC DOS Process Agent 47-27 195TH ST., FLUSHING, NY, United States, 11358

Licenses

Number Status Type Date End date
2059235-DCA Active Business 2017-10-12 2025-02-28
2017883-DCA Inactive Business 2015-02-03 2017-02-28

Filings

Filing Number Date Filed Type Effective Date
220325000785 2022-03-25 BIENNIAL STATEMENT 2020-04-01
200225060478 2020-02-25 BIENNIAL STATEMENT 2018-04-01
141113000509 2014-11-13 CERTIFICATE OF PUBLICATION 2014-11-13
140423010087 2014-04-23 ARTICLES OF ORGANIZATION 2014-04-23

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2024-09-20 No data PROSPECT PLACE, FROM STREET NOSTRAND AVENUE TO STREET ROGERS AVENUE No data Street Construction Inspections: Pick-Up Department of Transportation I observed a container in the parking lane without a permit to do so. Respondent failed to obtain a valid DOT permit before obstructing the parking lane. Respondent ID by DOB permit B01017487-I1-GC.
2024-09-18 No data FT HAMILTON PARKWAY, FROM STREET 68 STREET TO STREET BAY RIDGE AVENUE No data Street Construction Inspections: Complaint Department of Transportation I observed the above respondent/respondent's subcontractor has a wooden barricade obstructing the roadway, without a DOT permit on file. DOB permit #B01060429-I1-FD, used for ID.
2024-02-17 No data FINE BOULEVARD, FROM STREET ATHENA PLACE TO STREET TODT HILL ROAD No data Street Construction Inspections: Pick-Up Department of Transportation I OBSERVED RESPONDENT HAD PALLETS CONSTRUCTION MATERIALS & PALLETS OF BRICKS ON ROADWAY-WITHOUT A VALID DOT PERMIT. CONSTRUCTION MATERIALS ON STREET (ROADWAY)-NO PERMIT. NYC DEPT. OF BUILDINGS PERMIT#S08006572-I1-GC EXPIRES 6/09/2024 USED FOR ID.
2021-07-19 No data 51 AVENUE, FROM STREET 87 STREET TO STREET 90 STREET No data Street Construction Inspections: Post-Audit Department of Transportation Curb restored in kind
2021-06-15 No data 161 STREET, FROM STREET 45 AVENUE TO STREET 46 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb appears to have been restored in a semi monolithic manner. Properly restore/replace curb and installing and sealing expansion joint.
2020-02-25 No data 229 STREET, FROM STREET 58 AVENUE TO STREET HORACE HARDING EXPRESSWAY No data Street Construction Inspections: Pick-Up Department of Transportation I observed the above respondent stored a barricades on roadway and sidewalk on a construction site without a DOT building operation permit.DOB permit # 421922913-01-NB used to identify contractor.
2019-10-09 No data 120 STREET, FROM STREET 22 AVENUE TO STREET 23 AVENUE No data Street Construction Inspections: Pick-Up Department of Transportation I observed the above respondent occupy 11'x6' of the roadway on a construction site without a DOT building operation permit.DOB permit # 421928980-01-NB was used to identify the contractor.
2019-07-11 No data 215 PLACE, FROM STREET 39 AVENUE TO STREET 40 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb installed
2019-07-06 No data JUDGE STREET, FROM STREET ELMHURST AVENUE TO STREET VIETOR AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation curb installed
2019-06-12 No data 35 AVENUE, FROM STREET 108 STREET TO STREET 109 STREET No data Street Construction Inspections: Post-Audit Department of Transportation curb installed

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
3599445 TRUSTFUNDHIC INVOICED 2023-02-16 200 Home Improvement Contractor Trust Fund Enrollment Fee
3599546 RENEWAL INVOICED 2023-02-16 100 Home Improvement Contractor License Renewal Fee
3269296 TRUSTFUNDHIC INVOICED 2020-12-14 200 Home Improvement Contractor Trust Fund Enrollment Fee
3269297 RENEWAL INVOICED 2020-12-14 100 Home Improvement Contractor License Renewal Fee
2958701 RENEWAL INVOICED 2019-01-08 100 Home Improvement Contractor License Renewal Fee
2958700 TRUSTFUNDHIC INVOICED 2019-01-08 200 Home Improvement Contractor Trust Fund Enrollment Fee
2662844 LICENSE INVOICED 2017-09-06 75 Home Improvement Contractor License Fee
2662845 TRUSTFUNDHIC INVOICED 2017-09-06 200 Home Improvement Contractor Trust Fund Enrollment Fee
1952502 LICENSE INVOICED 2015-01-28 25 Home Improvement Contractor License Fee
1952503 TRUSTFUNDHIC INVOICED 2015-01-28 200 Home Improvement Contractor Trust Fund Enrollment Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346963580 0215600 2023-09-08 20-08 STEINWAY STREET, ASTORIA, NY, 11105
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2023-09-08
Emphasis N: FALL
Case Closed 2025-01-13

Related Activity

Type Complaint
Activity Nr 2117669
Safety Yes
Health Yes
Type Inspection
Activity Nr 1696362
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2024-01-17
Abatement Due Date 2024-01-29
Current Penalty 3687.0
Initial Penalty 3687.0
Final Order 2024-03-07
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: Worksite: 20-08 Steinway Street, Astoria, NY 11105 (Fourth Floor) On or about September 8th, 2023, an employee was exposed to an approximately 9-feet fall hazard while doing structure work on the edge of the steel form work without fall protection. Note: Abatement documentation is required. Pursuant to 29 CFR 1903.19.
342589769 0215600 2017-08-28 196-73 45TH ROAD, FLUSHING, NY, 11358
Inspection Type Prog Related
Scope Partial
Safety/Health Health
Close Conference 2017-08-28
Emphasis L: FALL, P: FALL
Case Closed 2018-04-04

Related Activity

Type Inspection
Activity Nr 1258980
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2018-02-27
Abatement Due Date 2018-04-13
Current Penalty 1000.0
Initial Penalty 2217.0
Final Order 2018-03-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): Employer had not developed, implemented, and maintained a written hazard communication program included in the requirements outlined in 29 CFR 1910.1200(e)(1)(I) and (e)(1)(II): (Construction Reference: 1926.59): (a) On or about August 28, 2017 at 196-73 45th Road, Flushing, NY 11358 The employer had not developed a written hazard communication program for employees using hazardous chemicals including, but not limited to, Lehigh Heidlberg Cement Group Masonry Cement, Type N containing Portland cement and hexavalent chromium to build the foundation of a 2 story residential home using cinder blocks. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19101200 G08
Issuance Date 2018-02-27
Abatement Due Date 2018-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-03-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they are readily accessible during each work shift to employees when they were in their work area(s): (Construction Reference: 1926.59) (a) On or about August 28, 2017 at 196-73 45th Road, Flushing, NY 11358 The employer did not maintain and provide to employees, copies of the required safety data sheets for each hazardous chemical including but not limited to, Lehigh Heidlberg Cement Group Masonry Cement, Type N containing Portland cement and hexavalent chromium to build the foundation of a 2 story residential home using cinder blocks. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2018-02-27
Abatement Due Date 2018-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-03-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): The Employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area: (Construction Reference: 1926.59) (a) On or about August 28, 2017 at 196-73 45th Road, Flushing, NY 11358 The employer did not provide hazardous communication information and training to employees who used hazardous chemicals including but not limited to, Lehigh Heidlberg Cement Group Masonry Cement, Type N containing Portland cement and hexavalent chromium to build the foundation of a 2 story residential home using cinder blocks. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2018-02-27
Abatement Due Date 2018-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-03-26
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D of 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (Construction Reference: 1926.103) (a) On or about August 28, 2017 at 196-73 45th Road, Flushing, NY 11358 The employer did not provide information on Appendix D of 29 CFR 1910.134 to employees who voluntarily used N95 dust masks for protection from silica dusts while cutting cinder blocks used to build the foundation of a 2 story residential home. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
342589801 0215600 2017-08-28 196-73 45TH ROAD, BAYSIDE, NY, 11361
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-08-28
Emphasis L: FALL, P: FALL
Case Closed 2018-06-04

Related Activity

Type Inspection
Activity Nr 1258976
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2018-02-27
Current Penalty 1800.0
Initial Penalty 2772.0
Final Order 2018-03-26
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided and not used wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact: (a) On or about August 28, 2017 at 196-73 45th Road, Flushing, NY 11358 Employees cutting cinder blocks with a Makita 9557PB angle grinder without the use of eye protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2018-02-27
Abatement Due Date 2018-04-13
Current Penalty 1800.0
Initial Penalty 2772.0
Final Order 2018-03-26
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: (a) On or about August 28, 2017 at 196-73 45th Road, Flushing, NY 11358 Employees cutting cinder blocks with a Makita 9557PB angle grinder without a guard. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 B01 II
Issuance Date 2018-02-27
Abatement Due Date 2018-04-13
Current Penalty 2500.0
Initial Penalty 3880.0
Final Order 2018-03-26
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): (a) On or about August 28, 2017 at 196-73 45th Road, Flushing, NY 11358. Employees preforming masonry work from a tubular welded frame scaffold that was not fully planked. The working level was approximately 18 feet from the lower level. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2018-02-27
Abatement Due Date 2018-04-13
Current Penalty 1800.0
Initial Penalty 2772.0
Final Order 2018-03-26
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): Protruding reinforcing steel, onto and into which employees could fall was not guarded to eliminate the hazard of impalement: (a) On or about August 28, 2017 at 196-73 45th Road, Flushing, NY 11358 Employees cutting cinder blocks next to rebar that was not capped. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2018-02-27
Abatement Due Date 2018-04-13
Current Penalty 5600.0
Initial Penalty 8536.0
Final Order 2018-03-26
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about August 28, 2017 at 196-73 45th Road, Flushing, NY 11358 Employees preforming masonry work from the leading edge of the second floor without fall protection. The working level was approximately 18 feet from the lower level. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. HY DESIGN & DEVELOPMENT LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 1926.501(b)(13) OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1175698, CITATION NUMBER 01 ITEM NUMBER 003A, ISSUED ON 10/17/2016 AND WAS AFFIRMED AS FINAL ORDER ON 11/14/2016, WITH RESPECT TO A WORKPLACE LOCATED AT 64-36 215TH STREET, OAKLAND GARDENS, NY 11364. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN ADDIONTIONAL OF $1,000.00 AS PER CFR 1903.19.
341756989 0215600 2016-09-08 61-36 215TH STREET, OAKLAND GARDENS, NY, 11364
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-09-08
Emphasis L: FALL, P: FALL
Case Closed 2017-02-02

Related Activity

Type Referral
Activity Nr 1133814
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2016-10-17
Abatement Due Date 2016-10-27
Current Penalty 2672.0
Initial Penalty 2672.0
Final Order 2016-11-14
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364 Employees were using a 2 receptacle outlet that was not mounted in a box, inside a wall, as it is designed. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19 b) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364 Employees were using a 4 outlet surge protector that is designed for indoor use, as extension cord at an outdoor construction site. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2016-10-17
Abatement Due Date 2016-10-27
Current Penalty 2672.0
Initial Penalty 2672.0
Final Order 2016-11-14
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364 employees were working on a tubular welded frame scaffold, approximately 20-feet above a lower level, that was not fully decked at the work level. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2016-10-17
Abatement Due Date 2016-10-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-11-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364 Employees were working on a tubular welded frame scaffold, approximately 20-feet above a lower level, that was supported on an unstable wooden platform. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2016-10-17
Abatement Due Date 2016-10-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-11-14
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364 Employees were working on a tubular welded frame scaffold that did not have base plates or mud sills installed. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2016-10-17
Abatement Due Date 2016-10-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-11-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364 Employees working on a tubular welded frame scaffold, approximately 20-feet above a lower level, climbed up and down the frame to access the work levels. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Citation ID 01002E
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2016-10-17
Abatement Due Date 2016-10-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-11-14
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364 Employees were working on a tubular welded frame scaffold, approximately 20-feet above a lower level, that was missing cross bracing at several positions on the scaffold. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-10-17
Abatement Due Date 2016-10-27
Current Penalty 2672.0
Initial Penalty 2672.0
Final Order 2016-11-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364 Employees were constructing a 2-story home and were working on the outside of the upper level, approximately 25-feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2016-10-17
Abatement Due Date 2016-10-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-11-14
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364 Employees were constructing a 2-story home and were working on the outside of the upper level, approximately 25-feet above the next lower level, without fall protection training. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19

Date of last update: 25 Mar 2025

Sources: New York Secretary of State