Search icon

BRUNGA CONSTRUCTION, INC.

Company Details

Name: BRUNGA CONSTRUCTION, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 28 Apr 2014 (11 years ago)
Entity Number: 4568710
ZIP code: 10710
County: Westchester
Place of Formation: New York
Address: 33 BEAUMONT CIRCLE, SUITE 3, YONKERS, NY, United States, 10710

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
ARBEN BRUNGA DOS Process Agent 33 BEAUMONT CIRCLE, SUITE 3, YONKERS, NY, United States, 10710

History

Start date End date Type Value
2014-04-28 2023-03-15 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
140428010422 2014-04-28 CERTIFICATE OF INCORPORATION 2014-04-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343782694 0216000 2019-02-08 209-215 VERNON AVE., YONKERS, NY, 10704
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2019-02-20
Case Closed 2023-04-14

Related Activity

Type Referral
Activity Nr 1426534
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2019-02-21
Current Penalty 243.0
Initial Penalty 1705.0
Contest Date 2019-03-13
Final Order 2019-08-12
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: location: front of building on or about: 2/8/19 a) Employees were working from a tubular welded frame scaffold. The working level of the scaffold was not fully decked. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2019-02-21
Current Penalty 243.0
Initial Penalty 1705.0
Contest Date 2019-03-13
Final Order 2019-08-12
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: location: front of building on or about: 2/8/19 a) Employees were working on a tubular welded frame scaffold. The employees were not provided with adequate access. The employees were climbing the walk through frames. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2019-02-21
Current Penalty 528.0
Initial Penalty 3978.0
Contest Date 2019-03-13
Final Order 2019-08-12
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level: location: front of building on or about: 2/8/19 a) Employees, engaged in stucco work from a tubular welded frame scaffold, were not provided with fall protection. The employees were exposed to a fall of up to 19 feet. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2019-02-21
Abatement Due Date 2019-09-12
Current Penalty 243.0
Initial Penalty 1705.0
Contest Date 2019-03-13
Final Order 2019-08-12
Nr Instances 3
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer shall have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: location: entire site on or about: 2/8/19 a) Employees were working from a tubular welded frame scaffold. The employees were not provided with scaffold safety training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2019-02-21
Abatement Due Date 2019-03-26
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-03-13
Final Order 2019-08-12
Nr Instances 3
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: location: entire site on or about: 2/8/19 a) Employees used the stairs in the front of the building. The open sided stairs did not have stairrails. The employees were not trained to recognize hazards associated with stairways. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2019-02-21
Current Penalty 243.0
Initial Penalty 1705.0
Contest Date 2019-03-13
Final Order 2019-08-12
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: location: front of building on or about: 2/8/19 a) Employees used the stairs in the front of the building. The open sided stairs did not have stairrails. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.

Date of last update: 25 Mar 2025

Sources: New York Secretary of State