Name: | BERTRAND'S CONSTRUCTION, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 30 Apr 2014 (11 years ago) |
Entity Number: | 4570210 |
ZIP code: | 13669 |
County: | St. Lawrence |
Place of Formation: | New York |
Address: | 304 HAYWARD ST, OGDENSBURG, NY, United States, 13669 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Plan Name | Plan Year | EIN/PN | Received | Sponsor | Total number of participants | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BERTRAND'S CONSTRUCTION, INC. | 2023 | 465598307 | 2024-04-19 | BERTRAND'S CONSTRUCTION, INC. | 6 | |||||||||||||
|
||||||||||||||||||
BERTRAND'S CONSTRUCTION, INC. | 2022 | 465598307 | 2023-07-24 | BERTRAND'S CONSTRUCTION, INC. | 7 | |||||||||||||
|
||||||||||||||||||
BERTRAND'S CONSTRUCTION, INC. | 2021 | 465598307 | 2022-05-17 | BERTRAND'S CONSTRUCTION, INC. | 0 | |||||||||||||
|
Name | Role | Address |
---|---|---|
NICOLAS BERTRAND | Chief Executive Officer | 304 HAYWARD ST, OGDENSBURG, NY, United States, 13669 |
Name | Role | Address |
---|---|---|
NICOLAS BERTRAND | DOS Process Agent | 304 HAYWARD ST, OGDENSBURG, NY, United States, 13669 |
Start date | End date | Type | Value |
---|---|---|---|
2014-04-30 | 2018-04-02 | Address | 304 HAYWARD STREET, OGDENSBURG, NY, 13669, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
200406060152 | 2020-04-06 | BIENNIAL STATEMENT | 2020-04-01 |
180402007841 | 2018-04-02 | BIENNIAL STATEMENT | 2018-04-01 |
140430010375 | 2014-04-30 | CERTIFICATE OF INCORPORATION | 2014-04-30 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346143787 | 0215800 | 2022-07-19 | 200 NEW YORK AVENUE, OGDENSBURG, NY, 13669 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2023-01-18 |
Current Penalty | 4688.0 |
Initial Penalty | 4688.0 |
Contest Date | 2023-02-13 |
Final Order | 2023-07-27 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 200 New York Avenue, Ogdensburg, NY 13669, on or about 7/19/22: Workers were performing roofing work on a 6:12 pitch roof with a ground to eave height of 8 feet without fall protection of any kind. |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19261053 B04 |
Issuance Date | 2023-01-18 |
Current Penalty | 0.0 |
Initial Penalty | 3349.0 |
Contest Date | 2023-02-13 |
Final Order | 2023-07-27 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) 200 New York Avenue, Ogdensburg, NY 13669, on or about 7/19/22: A worker was on an 8-foot step ladder that was leaning against the building facia, without the spreaders out and locked as is the design of this type of ladder. |
Inspection Type | Prog Related |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2018-11-06 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2019-03-15 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2019-02-21 |
Current Penalty | 0.0 |
Initial Penalty | 3978.0 |
Final Order | 2019-03-12 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a) At the jobsite, on the roof, on or about 11/6/19: Workers were using a JLG Aerial Lift to gain access to and lower from, a 6:12 pitch roof over 20 feet to ground without being attached to the boom or basket. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2019-02-21 |
Current Penalty | 0.0 |
Initial Penalty | 2842.0 |
Final Order | 2019-03-12 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the jobsite, on the roof, on or about 11/6/19: Workers were performing roofing work on a multiple pitch roof and dormer with a ground to eave height of 20 feet, without fall protection of any kind. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8791938501 | 2021-03-10 | 0248 | PPS | 304 Hayward St, Ogdensburg, NY, 13669-2045 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2514826 | Intrastate Non-Hazmat | 2024-06-04 | 2800 | 2024 | 4 | 2 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |