Number Type Date Last renew date End date Address Description
0340-22-211858 Alcohol sale 2022-11-01 2022-11-01 2024-11-30 33 BROADWAY, SARANAC LAKE, New York, 12983 Restaurant

Filings

Filing Number Date Filed Type Effective Date
140911000829 2014-09-11 CERTIFICATE OF PUBLICATION 2014-09-11
140509000766 2014-05-09 ARTICLES OF ORGANIZATION 2014-05-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340871144 0215800 2015-08-20 33 BROADWAY, SARANAC LAKE, NY, 12983
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2015-08-20
Emphasis L: LOCALTARG, P: LOCALTARG
Case Closed 2015-11-11

Related Activity

Type Inspection
Activity Nr 1087122
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260304 H01
Issuance Date 2015-10-16
Abatement Due Date 2015-10-26
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2015-11-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: a) At the jobsite, on or about 8/20/15: Workers were using a Makita table saw withouot a guard on the blade. Abatement certification must be submitted for this item.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2015-10-16
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2015-11-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around the hole: a) At the jobsite, on or about 8/20/15: Workers were exposed to falling 10 feet to the lower level where a stairway had been removed and the opening remained unprotected.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260502 B01
Issuance Date 2015-10-16
Current Penalty 0.0
Initial Penalty 2000.0
Final Order 2015-11-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a) At the jobsite, on or about 8/20/15: Employees were working in close proximity to and transiting past a guardrail that measured only 32 inches from the walking surface, and had no midrail.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260502 B02 I
Issuance Date 2015-10-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-11-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(2)(i): Midrails, when used, were not installed at a height midway between the top edge of the guardrail system and the walking/working level; screens and mesh, when used, did not extend from the top rail to the walking/working level and along the entire opening between top rail supports: a) At the jobsite, on or about 8/20/15: Employees were working in close proximity to and transiting past a guardrail that measured only 32 inches from the walking surface, and had no midrail.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19261052 C01 I
Issuance Date 2015-10-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-11-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) At the jobsite, on or about 8/20/15: Employees were working in close proximity to and using a stair well that had no guardrails.