Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-06-08
|
Emphasis |
L: FALL, P: FALL, L: GUTREH
|
Case Closed |
2017-01-30
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2015-06-11 |
Current Penalty |
0.0 |
Initial Penalty |
1200.0 |
Contest Date |
2015-07-06 |
Final Order |
2016-11-23 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 6/8/15 at a building rehabilitation project located at 128 3rd Street, Niagara Falls, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2015-06-11 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Contest Date |
2015-07-06 |
Final Order |
2016-11-23 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) On or about 6/8/15 at a building rehabilitation project located at 128 3rd Street, Niagara Falls, New York; employees working on the roof with a pitch of approximately 2 in 12 were not protected from falling approximately 12 feet. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2015-06-11 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Contest Date |
2015-07-06 |
Final Order |
2016-11-23 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 6/8/15 at a building rehabilitation project located at 128 3rd Street, Niagara Falls, New York; employees were accessing a roof from the front of the building using an extension ladder that had it's side rails approximately 18 inches above the landing surface. NO ABATEMENT CERTIFICATION REQUIRED |
|
|