Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-11-18
|
Emphasis |
L: FALL
|
Case Closed |
2019-07-03
|
Related Activity
Type |
Complaint |
Activity Nr |
1040308 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2015-12-08 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-03-07 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: On or about 11/16/2015, Columbus Ave. a) The employees were engaged in framing canopies and were not provided training as required by the standard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
2015-12-08 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-03-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: On or about 11/16/2015, Columbus Ave. a) The employees used a 100' extension cord to power the Makita skilsaw. They were not using a ground fault circuit interrupter. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2015-12-08 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-03-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: On 11/16/2015, Columbus Ave. a) Three employees were on a tubular welded frame scaffold, approximately 18' high without guardrails. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B08 |
Issuance Date |
2015-12-08 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-03-07 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: On or about 11/16/2015, Columbus Ave. a) The employees used the 16' aluminum extension ladder to gain access to and from the work area. The ladder was not secured to prevent displacement. |
|
|