Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-07-20
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2018-08-30
|
Related Activity
Type |
Inspection |
Activity Nr |
1249367 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260304 F |
Issuance Date |
2017-08-11 |
Current Penalty |
1629.96 |
Initial Penalty |
2716.0 |
Final Order |
2018-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) East side of building, on or about 7-20-17: One employee was ripping plywood on a table saw that was not equipped with a spreader. b) East side of building, on or about 7-20-17: One employee was ripping plywood on a table saw that was not equipped with non kick-back fingers or "dogs". c) East side of building, on or about 7-20-17: One employee was ripping plywood on a table saw that was not equipped with a magnetic switch or anti-restart device. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260304 I01 |
Issuance Date |
2017-08-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) East side of building, on or about 7-20-17: One employee was ripping plywood on a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade. |
|
|