Search icon

CENTURION SOLAR ENERGY, LLC

Branch

Company Details

Name: CENTURION SOLAR ENERGY, LLC
Jurisdiction: New York
Legal type: FOREIGN LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 10 Sep 2014 (11 years ago)
Branch of: CENTURION SOLAR ENERGY, LLC, Connecticut (Company Number 1085393)
Entity Number: 4633772
ZIP code: 10017
County: Westchester
Place of Formation: Connecticut
Address: 575 Fifth Avenue, 14th Floor, Suite 17-115, New York, NY, United States, 10017

Contact Details

Phone +1 203-246-0947

DOS Process Agent

Name Role Address
CENTURION SOLAR ENERGY, LLC DOS Process Agent 575 Fifth Avenue, 14th Floor, Suite 17-115, New York, NY, United States, 10017

Licenses

Number Status Type Date End date
2031611-DCA Active Business 2015-12-22 2025-02-28

History

Start date End date Type Value
2023-08-16 2024-09-03 Address 12 East 49th Street, 11th Floor, Suite 10-111, New York, NY, 10017, USA (Type of address: Service of Process)
2014-09-10 2023-08-16 Address 498 DEN RD., BLDG 2, STAMFORD, CT, 06903, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
240903003770 2024-09-03 BIENNIAL STATEMENT 2024-09-03
230816000134 2023-08-16 BIENNIAL STATEMENT 2022-09-01
141119000903 2014-11-19 CERTIFICATE OF PUBLICATION 2014-11-19
140910000102 2014-09-10 APPLICATION OF AUTHORITY 2014-09-10

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
3586988 TRUSTFUNDHIC INVOICED 2023-01-24 200 Home Improvement Contractor Trust Fund Enrollment Fee
3586989 RENEWAL INVOICED 2023-01-24 100 Home Improvement Contractor License Renewal Fee
3283438 TRUSTFUNDHIC INVOICED 2021-01-14 200 Home Improvement Contractor Trust Fund Enrollment Fee
3281919 RENEWAL INVOICED 2021-01-11 100 Home Improvement Contractor License Renewal Fee
2977088 RENEWAL INVOICED 2019-02-06 100 Home Improvement Contractor License Renewal Fee
2473306 RENEWAL INVOICED 2016-10-18 100 Home Improvement Contractor License Renewal Fee
2234587 LICENSE INVOICED 2015-12-15 75 Home Improvement Contractor License Fee
2234591 FINGERPRINT INVOICED 2015-12-15 75 Fingerprint Fee
2234588 TRUSTFUNDHIC INVOICED 2015-12-15 200 Home Improvement Contractor Trust Fund Enrollment Fee
2234595 FINGERPRINT INVOICED 2015-12-15 75 Fingerprint Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343019964 0216000 2018-03-14 67 FLORENCE ST., YONKERS, NY, 10704
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2018-03-16
Emphasis L: FALL, P: FALL
Case Closed 2023-02-06

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-03-20
Current Penalty 5174.0
Initial Penalty 5174.0
Final Order 2018-04-19
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Location: roof On or about: 3/14/18 a) Employees, installing solar panels, were not using with fall protection. The employees were exposed to a fall of between 15' and 17'. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2018-03-20
Abatement Due Date 2018-04-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 4
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards: Location: entire site On or about: 3/14/18 a) Employees, exposed to fall hazards while installing solar panels, were not provided with adequate fall protection training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2018-03-20
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2018-04-19
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: location: front of house on or about: 3/14/18 a) Employees were gaining access to and from the roof using a ladder that extended less than 2 feet above the upper landing surface. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.

Date of last update: 25 Mar 2025