347427247
|
0214700
|
2024-04-19
|
250 ROUND SWAMP ROAD, MELVILLE, NY, 11747
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-04-19
|
Emphasis |
N: FALL, P: FALL
|
Related Activity
Type |
Inspection |
Activity Nr |
1742735 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2024-10-17 |
Abatement Due Date |
2024-10-23 |
Current Penalty |
4149.0 |
Initial Penalty |
4149.0 |
Final Order |
2024-11-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii):Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite, Equestrian Estates, 250 Round Swamp Road, Melville, NY, 11747- Employee was installing roof rafters on a residential home while working from a job made work platform approximately 14-feet above the next lower level without the use of fall protection; on or about April 19, 2024. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-10-17 |
Abatement Due Date |
2024-10-23 |
Current Penalty |
4149.0 |
Initial Penalty |
4149.0 |
Final Order |
2024-11-13 |
Nr Instances |
2 |
Nr Exposed |
3 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, Equestrian Estates, 250 Round Swamp Road, Melville, NY, 11747: Employee was working on the second floor of a 3-story residential private dwelling passing wood rafters up to the third floor. The employee was working from the edge approximately 12-feet above the ground without a means of fall protection; on or about April 19, 2024. b) Worksite, Equestrian Estates, 250 Round Swamp Road, Melville, NY, 11747- Employees were working on the third floor of a 3-story residential private dwelling. Employees were installing roof rafters while standing on the edge, approximately 10-feet above the lower level without a means of fall protection; on or about April 19, 2024. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|
346662240
|
0214700
|
2023-04-26
|
4180 SUNRISE HIGHWAY, OAKDALE, NY, 11769
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-04-26
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-10-05
|
Related Activity
Type |
Inspection |
Activity Nr |
1666121 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1666205 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1666190 |
Safety |
Yes |
|
|
344143623
|
0214700
|
2019-07-10
|
4 ROBINS ROAD, CENTRAL ISLIP, NY, 11722
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-07-10
|
Emphasis |
L: FALL
|
Related Activity
Type |
Inspection |
Activity Nr |
1414388 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1414283 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1415016 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1414275 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1414681 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1414659 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1414563 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1413851 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1414624 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B09 |
Issuance Date |
2019-10-02 |
Current Penalty |
3789.0 |
Initial Penalty |
3789.0 |
Final Order |
2019-12-11 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(9): The area around the top and/or bottom of (a) ladder(s) was not kept clear: a) Worksite, 4 Robins Road, Central Islip, New York - Employees were accessing a portable extension ladder and the top of the ladder was not kept clear of an overextended guardrail; on or about 07/10/2019. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261053 B15 |
Issuance Date |
2019-10-02 |
Abatement Due Date |
2019-10-08 |
Current Penalty |
3789.0 |
Initial Penalty |
3789.0 |
Final Order |
2019-12-11 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: a) Worksite, 4 Robins Road, Central Islip, New York - Employees were using a portable WERNER extension ladder to access the second level of the residential building, approximately 10ft above the ground, and it was not inspected by a competent person for visible defects. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261053 B16 |
Issuance Date |
2019-10-02 |
Abatement Due Date |
2019-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-12-11 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. a) Worksite, 4 Robins Road, Central Islip, New York - Employees were accessing a portable extension ladder with missing cleats on the base of the ladder, on or about 07/10/2019. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|