Search icon

BENNETT CONSTRUCTION MANAGEMENT, INC.

Company Details

Name: BENNETT CONSTRUCTION MANAGEMENT, INC.
Jurisdiction: New York
Legal type: FOREIGN BUSINESS CORPORATION
Status: Active
Date of registration: 29 Sep 2014 (11 years ago)
Entity Number: 4643022
ZIP code: 10005
County: New York
Place of Formation: Ohio
Address: 28 LIBERTY ST., NEW YORK, NY, United States, 10005

Agent

Name Role Address
C T CORPORATION SYSTEM Agent 28 LIBERTY ST., NEW YORK, NY, 10005

DOS Process Agent

Name Role Address
C T CORPORATION SYSTEM DOS Process Agent 28 LIBERTY ST., NEW YORK, NY, United States, 10005

History

Start date End date Type Value
2014-09-29 2019-01-28 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Registered Agent)
2014-09-29 2019-01-28 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
SR-68886 2019-01-28 CERTIFICATE OF CHANGE (BY AGENT) 2019-01-28
SR-68887 2019-01-28 CERTIFICATE OF CHANGE (BY AGENT) 2019-01-28
140929000121 2014-09-29 APPLICATION OF AUTHORITY 2014-09-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340047190 0213100 2014-10-29 CORNER OF BALLTOWN RD. AND ROUTE 5, SCHENECTADY, NY, 12304
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-10-29
Emphasis L: FALL, P: FALL
Case Closed 2015-01-28

Related Activity

Type Inspection
Activity Nr 1004878
Safety Yes
Type Inspection
Activity Nr 1004753
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2014-11-17
Current Penalty 2500.0
Initial Penalty 3850.0
Final Order 2014-12-12
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: a) ) On or about October 29, 2014 at the jobsite at the north east corner of Route 5 and Balltown Road in the Town of Niskayuna an aerial lift was being used by 3 workers of a subcontractor to a subcontractor to this employer at an elevation of approximately 20 feet without the workers each wearing body belts or personal fall arrest systems. They also were all not attached by lanyards to the aerial lift. Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated: