OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345272777 0213100 2021-04-23 116 CIRCULAR ST., SARATOGA SPRINGS, NY, 12866
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-04-28
Emphasis L: FALL, P: FALL
Case Closed 2024-01-16

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2021-05-07
Current Penalty 2341.0
Initial Penalty 2341.0
Final Order 2021-06-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Building Roof - On or about April 23, 2021 and at times prior thereto, employees were exposed to overhead hazards while working underneath roofers on the second floor roof without the use of hard hats.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2021-05-07
Current Penalty 4096.0
Initial Penalty 4096.0
Final Order 2021-06-02
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Building roof - On or about April 23, 2021 and at times prior thereto, employees were performing roofing work without the use of adequate fall protection, either using no protection, or wearing a body belt connected to a rope grab system, or holding onto a rope with ones hand for support.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2021-05-07
Current Penalty 2926.0
Initial Penalty 2926.0
Final Order 2021-06-02
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Building roof - On or about April 23, 2021 and at times prior thereto, employees were accessing the roof using extension ladders that did not extend 3 feet above the landing surface, only extending approximately 1 foot.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2021-05-07
Abatement Due Date 2021-05-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-06-02
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a) Building roof - On or about April 23, 2021 and at times prior thereto, employees were performing roofing work without the use of adequate fall protection. Employees had received fall protection training but the employer did not have a written certification of such training.

Date of last update: 08 Mar 2025

Sources: New York Secretary of State