347834608
|
0215000
|
2024-10-21
|
1440 AMSTERDAM AVE., NEW YORK, NY, 10027
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-10-21
|
Emphasis |
L: LOCALTARG
|
|
343394938
|
0215000
|
2018-08-14
|
211 MCGUINNESS BLVD, BROOKLYN, NY, 11222
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-08-14
|
Emphasis |
L: FALL
|
Case Closed |
2020-09-10
|
Related Activity
Type |
Inspection |
Activity Nr |
1337609 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1345424 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2019-02-14 |
Current Penalty |
2000.0 |
Initial Penalty |
2842.0 |
Final Order |
2019-02-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed a) An employee was exposed to fall hazard when using an 8 ft stepladder was used to access an 11 ft high platform over the entrance door to the building. The ladder was not tall enough to provide safe access. Location: 211 McGuinness Blvd, Brooklyn NY On or about 8/14/2018 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2019-02-14 |
Current Penalty |
2000.0 |
Initial Penalty |
2842.0 |
Final Order |
2019-02-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) The employee was exposed to fall hazard when standing on the top of an 8 ft stepladder. Location: 211 McGuinness Blvd, Brooklyn NY On or about 8/14/2018 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19. |
|
|
343104204
|
0215000
|
2018-04-23
|
554 4TH AVE, BROOKLYN, NY, 11215
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-04-23
|
Case Closed |
2018-05-14
|
Related Activity
Type |
Inspection |
Activity Nr |
1233103 |
Safety |
Yes |
|
|
342331030
|
0215000
|
2017-05-17
|
554 4TH AVE, BROOKLYN, NY, 11215
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-05-17
|
Emphasis |
L: FALL
|
Case Closed |
2018-05-17
|
Related Activity
Type |
Complaint |
Activity Nr |
1215301 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1233476 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
2017-08-15 |
Abatement Due Date |
2017-08-23 |
Current Penalty |
3984.0 |
Initial Penalty |
3984.0 |
Final Order |
2017-09-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. a) 3rd Floor NW corner: On or about May 17, 2017 The framer was using a Dewalt chop saw which was plugged in by an extension cord. The extension cord was tested and was not protected by GFCI |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2017-08-15 |
Abatement Due Date |
2017-08-23 |
Current Penalty |
3984.0 |
Initial Penalty |
3984.0 |
Final Order |
2017-09-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a) 3rd Floor NW corner: On or about May 17, 2017 The framer was using a Dewalt chop saw which was plugged in by an extension cord. The extension cord was missing the ground pin. |
|
|
341273639
|
0215000
|
2016-02-23
|
100 NORFOLK ST., NEW YORK, NY, 10002
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-02-23
|
Emphasis |
N: AMPUTATE, L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2016-08-01
|
Related Activity
Type |
Inspection |
Activity Nr |
1127360 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1127371 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1127377 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260303 B01 |
Issuance Date |
2016-04-14 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2016-05-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels: a) 100 Norfolk St., NY, NY - 4th floor: On or about 02/23/2016 an MEC Construction employee was using a Hilti AG 450-7 angle grinder with abrasive blade to cut metal framing studs. The blade of the grinder not guarded in any manner, exposing the employee to laceration hazards. |
|
|
313001919
|
0216000
|
2010-03-25
|
652 HAVERSTRAW ROAD, MONTEBELLO, NY, 10901
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2010-03-25
|
Emphasis |
S: HISPANIC, S: RESIDENTIAL CONSTR, S: ELECTRICAL, L: FALL
|
Case Closed |
2010-11-16
|
Related Activity
Type |
Referral |
Activity Nr |
202754586 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2010-08-18 |
Abatement Due Date |
2010-08-23 |
Current Penalty |
312.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260416 E01 |
Issuance Date |
2010-08-18 |
Abatement Due Date |
2010-08-23 |
Current Penalty |
312.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2010-08-18 |
Abatement Due Date |
2010-08-23 |
Current Penalty |
514.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260452 W02 |
Issuance Date |
2010-08-18 |
Abatement Due Date |
2010-08-23 |
Current Penalty |
212.0 |
Initial Penalty |
225.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
314070426
|
0215000
|
2009-12-10
|
214 GREEN ST, BROOKLYN, NY, 11222
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2009-12-10
|
Emphasis |
L: CONSTLOC
|
Case Closed |
2009-12-10
|
|