Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-01-15
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2021-09-19
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260034 C |
Issuance Date |
2020-05-01 |
Abatement Due Date |
2020-05-07 |
Current Penalty |
1700.0 |
Initial Penalty |
2892.0 |
Final Order |
2020-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency. Location: 265 West 131st Street, New York, NY 10027 On or about: January 15, 2020 (a) Construction fence doors used as means of egress were locked by chains and locks. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260403 I02 I |
Issuance Date |
2020-05-01 |
Abatement Due Date |
2020-05-07 |
Current Penalty |
1700.0 |
Initial Penalty |
2892.0 |
Final Order |
2020-11-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. Location: 265 West 131st Street, New York, NY 10027 On or about: January 15, 2020 (a) An electrical panel with live components was not equipped with a cover to guard against accidental contact. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260405 J01 I |
Issuance Date |
2020-05-01 |
Abatement Due Date |
2020-05-07 |
Current Penalty |
1700.0 |
Initial Penalty |
2892.0 |
Final Order |
2020-11-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact: Location: 265 West 131st Street, New York, NY 10027 On or about: January 15, 2020 (a) Receptacles with live parts exposed to employee contact were used to energize equipment such a microwave, a portable heater, and a RotoZip SS355. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260405 J01 II |
Issuance Date |
2020-05-01 |
Abatement Due Date |
2020-05-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-11-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported: Location: 265 West 131st Street, New York, NY 10027 On or about: January 15, 2020 (a) Receptacles that were not securely supported and mounted were used to energize equipment such as a microwave, a portable heater, and a RotoZip SS355; live parts were exposed to employee contact. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19261052 C12 |
Issuance Date |
2020-05-01 |
Abatement Due Date |
2020-05-07 |
Current Penalty |
3100.0 |
Initial Penalty |
4048.0 |
Final Order |
2020-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS) (IDENTIFY AND SPECIFY SPECIFIC SECTION OF SUBPART M NOT COMPLIED WITH)Note: Guarding of landings for stairways and ladders are being maintained under Subpart M. Location: 265 West 131st Street, New York, NY 10027 On or about: January 15, 2020 (a) Employees walking on the top landing of the main entrance stairway were exposed to falls of up to approximately 8 feet to lower levels. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19261052 C07 |
Issuance Date |
2020-05-01 |
Abatement Due Date |
2020-05-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-11-19 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(7): The top edge of a stairrail system served as a handrail and the height of the top edge was less than 36 inches (91.5 cm) from the upper surface of the stairrail system to the surface of the tread, in line with the face of the riser. Location: 265 West 131st Street, New York, NY 10027 On or about: January 15, 2020 (a) The top edge of a stair rail system, that also served as a handrail, was approximately 14.5 inches from the upper surface of the stair rail system to the surface of the tread. |
|
|