Search icon

BRUDSTONE BUILDING & REMODELING INC.

Company Details

Name: BRUDSTONE BUILDING & REMODELING INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 12 Jan 2015 (10 years ago)
Entity Number: 4692552
ZIP code: 14226
County: Erie
Place of Formation: New York
Address: 6000 NORTH BAILEY AVENUE, SUITE 1A, AMHERST, NY, United States, 14226

Shares Details

Shares issued 1000

Share Par Value 0.01

Type PAR VALUE

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
BRUDSTONE BUILDING & REMODELING, INC. 401(K) PLAN 2016 472926157 2017-10-09 BRUDSTONE BUILDING & REMODELING, INC. 1
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2015-01-01
Business code 236110
Sponsor’s telephone number 7169098073
Plan sponsor’s address 233 FILLMORE AVENUE, SUITE 10, TONAWANDA, NY, 14150

Signature of

Role Plan administrator
Date 2017-10-09
Name of individual signing MICHAEL WILLIAMS
BRUDSTONE BUILDING & REMODELING, INC. 401(K) PLAN 2015 472926157 2016-09-29 BRUDSTONE BUILDING & REMODELING, INC. 1
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2015-01-01
Business code 236110
Sponsor’s telephone number 7169098073
Plan sponsor’s address 233 FILLMORE AVENUE, SUITE 10, TONAWANDA, NY, 14150

Signature of

Role Plan administrator
Date 2016-09-28
Name of individual signing MICHAEL WILLIAMS

Agent

Name Role Address
SETH ANDREWS, ESQ. Agent 6000 NORTH BAILEY AVENUE, SUITE 1A, AMHERST, NY, 14226

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 6000 NORTH BAILEY AVENUE, SUITE 1A, AMHERST, NY, United States, 14226

Filings

Filing Number Date Filed Type Effective Date
150112000678 2015-01-12 CERTIFICATE OF INCORPORATION 2015-01-12

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341564508 0213600 2016-06-20 90 CROSBY BOULEVARD, AMHERST, NY, 14226
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2016-08-01
Emphasis L: FALL
Case Closed 2023-05-08

Related Activity

Type Referral
Activity Nr 1103710
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2016-08-01
Abatement Due Date 2016-08-31
Current Penalty 1100.0
Initial Penalty 2000.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 06/20/16, on a construction site at a house undergoing renovations at 90 Crosby Blvd., Amherst,NY: Employees engaged in construction work including demolition, roofing & siding work , and general renovation work were not trained to recognize potential hazards on this type of jobsite, including but not limited to falls from roofs, ladders, skylights, stairs & scaffolds, electrical hazards, unguarded tools/machines, fire hazards, and the need for personal protective equipment to protect them from various hazards. They also were not trained in the applicable OSHA regulations to control or eliminate these hazards. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2016-08-01
Abatement Due Date 2016-08-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) On or about 06/20/16, on a construction site at a house undergoing renovations at 90 Crosby Blvd., Amherst,NY: Two untrained employees had erected a ladder jack scaffold approx. 13 ft. above the ground. The scaffold was not erected under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2016-08-01
Current Penalty 880.0
Initial Penalty 1600.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: On or about 06/20/16, on a construction site at a house undergoing renovations at 90 Crosby Blvd., Amherst,NY. A ladder jack scaffold was erected with the brackets on the outside (street side) of the support ladders. The employee had to climb over the bracket to get on the pik which was approx. 13 ft. above the ground. A separate access ladder was not provided. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 G01 I
Issuance Date 2016-08-01
Current Penalty 1560.0
Initial Penalty 2800.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: On or about 06/20/16, on a construction site at a house undergoing renovations at 90 Crosby Blvd., Amherst,NY: An employee was on the pik of a ladder jack scaffold erected on the south side of a house, west of the front entrance while engaged in removing rotted wood trim from a dormer on the roof. The employee fell approx. 13 ft. to the ground when the scaffold collapsed. No personal fall arrest system or other fall protection system was utilized. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260451 B05 II
Issuance Date 2016-08-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantlivered end: On or about 06/20/16, on a construction site at a house undergoing renovations at 90 Crosby Blvd., Amherst,NY: An employee was on the approx. 16 ft. long pik of a ladder jack scaffold erected on the south side of a house, west of the front entrance while engaged in removing rotted wood trim from a dormer on the roof. The pik extended over the end of the west support bracket by approx. 5 ft. and extended over the end of the east support bracket by approx. 1 ft. The employee was on the west cantlevered part of the pik when the scaffold collapsed and the employee fell approx. 13 ft. to the ground. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B04 II
Issuance Date 2016-08-01
Current Penalty 660.0
Initial Penalty 1200.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: a) On or about 06/20/16, on a construction site at a house undergoing renovations at 90 Crosby Blvd., Amherst,NY: There was an approx. 2 ft. deep pit with 2 PVC vertical pipes sticking out, at a wall corner west of the front entrance. The pit was covered by steel grating. There were two holes in grating, and there were 2 pieces of OSB/plywood PARTIALLY covering the holes. Neither cover was secured and neither was marked with the word Hole. NO ABATEMENT CERTIFICATION REQUIRED