Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-11-28
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2023-01-03
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2019-01-11 |
Current Penalty |
973.05 |
Initial Penalty |
1497.0 |
Final Order |
2019-02-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. 5, 3, 1 Ordelia Lane, during framing: On or prior to 11/28/18, employees were not wearing eye protection during use of pneumatic nail guns. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2019-01-11 |
Current Penalty |
1297.4 |
Initial Penalty |
1996.0 |
Final Order |
2019-02-05 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 5, 3, 1 Ordelia lane, during framing -- On or prior to 11/28/18, employees were exposed to fall hazards of 8 to 16 feet from the second floor of the building while installing OSB sheathing; no fall protection system was in use. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260100 A |
Issuance Date |
2019-01-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-02-05 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: 5, 3, 1 Ordelia, during framing -- Employees were not wearing hard hats for protection from head injury. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260416 E01 |
Issuance Date |
2019-01-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-02-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) 5, 3, 1 Ordelia lane, during framing -- On or prior to 11/28/18, extension cords with visible damage to outer jacket insulation were in use. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19261053 B16 |
Issuance Date |
2019-01-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-02-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. (a) 5, 3, 1 Ordelia lane, during framing: On or prior to 11/28/18, a Werner 16 foot aluminum extension ladder with a damaged extension mechanism was in use. |
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-04-20
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-08-10
|
Related Activity
Type |
Inspection |
Activity Nr |
1226321 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1226302 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1226307 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260502 B02 |
Issuance Date |
2017-06-30 |
Current Penalty |
1250.0 |
Initial Penalty |
2770.0 |
Final Order |
2017-07-13 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high. a) On the south side of the construction site, adjacent to the elevator shaft - On or about April 20, 2017, employees constructed a ramp that did not have midrails that were half-way between the toprail and the base of the ramp. |
|
|