Filing Number Date Filed Type Effective Date
150113010219 2015-01-13 CERTIFICATE OF INCORPORATION 2015-01-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343466488 0213600 2018-09-12 80 ELK STREET, BUFFALO, NY, 14210
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-09-12
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2018-09-18
Current Penalty 1663.0
Initial Penalty 1663.0
Final Order 2018-10-15
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 9/12/18 at a roof project located at 80 Elk Street, Buffalo, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 I
Issuance Date 2018-09-18
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2018-10-15
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 9/12/18 at a roof project located at 80 Elk Street, Buffalo, New York; employees performing roofing activities from a ladder jack scaffold approximately 18 feet high and were not protected from falling by a personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2018-09-18
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2018-10-15
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 9/12/18 at a roof project located at 80 Elk Street, Buffalo, New York; employees were placing shingles on the roof of a two story house. The roof had a 10 in 12 pitch and an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED