Name: | QUEEN CITY HOME PROS LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 28 Jan 2015 (10 years ago) |
Entity Number: | 4701254 |
ZIP code: | 14052 |
County: | Erie |
Place of Formation: | New York |
Address: | 955 MILL ROAD, EAST AURORA, NY, United States, 14052 |
Name | Role | Address |
---|---|---|
QUEEN CITY HOME PROS LLC | DOS Process Agent | 955 MILL ROAD, EAST AURORA, NY, United States, 14052 |
Start date | End date | Type | Value |
---|---|---|---|
2015-01-28 | 2021-01-11 | Address | 308 EISENHOWER, ANGOLA, NY, 14006, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
210111060579 | 2021-01-11 | BIENNIAL STATEMENT | 2021-01-01 |
150128010179 | 2015-01-28 | ARTICLES OF ORGANIZATION | 2015-01-28 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344226873 | 0213600 | 2019-08-12 | 2167 GENESEE STREET, BUFFALO, NY, 14211 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2019-09-17 |
Current Penalty | 1932.0 |
Initial Penalty | 1932.0 |
Final Order | 2019-10-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 08/12/19, on jobsite at a house at 2167 Genesee St., Buffalo, NY: Employees used an extension ladder to access the "pik" of a ladder jack scaffold erected on the east side of the house. The siderails of that extension ladder only extended approx. 20 inches above the edge of the pik. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 02001 |
Citaton Type | Repeat |
Standard Cited | 19260451 G01 I |
Issuance Date | 2019-09-17 |
Current Penalty | 4546.0 |
Initial Penalty | 4546.0 |
Final Order | 2019-10-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 08/12/19, on jobsite at a house at 2167 Genesee St., Buffalo, NY: Two employees were exposed to a potential fall of approx. 15 ft. from the pik on a Ladder Jack Scaffold erected on the east side of the house. The employees on the pik were removing the gutter. No Fall protection system was being utilized. NO ABATEMENT DOCUMENTATION REQUIRED Queen City Home Pros was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1248925, citation number 1, item number 2a, and was affirmed as a final order on 5/14/2018, with respect to a workplace located at 1529 South Park Avenue, Buffalo, NY 14220. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2017-07-10 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2018-07-02 |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260100 A |
Issuance Date | 2017-09-28 |
Current Penalty | 0.0 |
Initial Penalty | 1385.0 |
Contest Date | 2017-10-23 |
Final Order | 2018-05-14 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 7/10/17 at a roof replacement project located at 1529 South Park Avenue, Buffalo, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260451 G01 I |
Issuance Date | 2017-09-28 |
Current Penalty | 1800.0 |
Initial Penalty | 2309.0 |
Contest Date | 2017-10-23 |
Final Order | 2018-05-14 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 7/10/17 at a roof replacement project located at 1529 South Park Avenue, Buffalo, New York; employees performing roofing activities from a ladder jack scaffold approximately 18 feet high were not protected from falling by a personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2017-09-28 |
Current Penalty | 0.0 |
Initial Penalty | 2309.0 |
Contest Date | 2017-10-23 |
Final Order | 2018-05-14 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 7/10/17 at a roof replacement project located at 1529 South Park Avenue, Buffalo, New York; employees working on the roof were placing shingles on the roof of a two story house. The roof had a 10 in 12 pitch and an eave heights of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4984858303 | 2021-01-23 | 0296 | PPS | 955 Mill Rd, East Aurora, NY, 14052-2835 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
8360717104 | 2020-04-15 | 0296 | PPP | 955 Mill, buffalo, NY, 14052 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2527812 | Intrastate Non-Hazmat | 2023-05-08 | 10000 | 2022 | 3 | 2 | Auth. For Hire | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 2 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | .75 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 2 |
Vehicle Maintenance BASIC Roadside Performance measure value | 7.5 |
Total Number of Vehicle Inspections for the measurement period | 2 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 1 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 1 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 2 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Inspections
Unique report number of the inspection | D507900503 |
State abbreviation that indicates the state the inspector is from | NY |
The date of the inspection | 2024-03-22 |
ID that indicates the level of inspection | Full |
State abbreviation that indicates where the inspection occurred | NY |
Time weight of the inspection | 2 |
Number of Out-Of-Service violations related to Driver | 1 |
Number of Out-Of-Service violations related to vehicle | 0 |
Number of violations related to Hazardous Materials | 0 |
Total number of Out-Of-Service violations | 1 |
Total number of Out-Of-Service violations related to Hazardous Materials | 0 |
Description of the type of the main unit | STRAIGHT TRUCK |
Description of the make of the main unit | CHEVROLET |
License plate of the main unit | 16010ML |
License state of the main unit | NY |
Vehicle Identification Number of the main unit | 1GB3KYCG5JF109796 |
Unsafe Driving BASIC inspection | Y |
Hours-of-Service Compliance BASIC inspection | Y |
Driver Fitness BASIC inspection | Y |
Controlled Substances/Alcohol BASIC inspection | Y |
Vehicle Maintenance BASIC inspection | Y |
Total number of BASIC violations | 3 |
Number of Unsafe Driving BASIC violations | 0 |
Number of Hours-of-Service Compliance BASIC violations | 0 |
Number of Driver Fitness BASIC violations | 1 |
Number of Controlled Substances/Alcohol BASIC violations | 0 |
Number of Vehicle Maintenance BASIC violations | 2 |
Number of Hazardous Materials Compliance BASIC violations | 0 |
Violations
The date of the inspection | 2024-03-22 |
Code of the violation | 39617CPI |
Name of the BASIC | Vehicle Maintenance |
The violation is identified as Out-Of-Service violation | N |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 0 |
The severity weight that is assigned to a violation | 4 |
The time weight that is assigned to a violation | 2 |
The description of a violation | Operating a CMV without documentation of a periodic inspection |
The description of the violation group | Inspection Reports |
The unit a violation is cited against | Vehicle main unit |
The date of the inspection | 2024-03-22 |
Code of the violation | 39375CTAOTDLT232 |
Name of the BASIC | Vehicle Maintenance |
The violation is identified as Out-Of-Service violation | N |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 0 |
The severity weight that is assigned to a violation | 8 |
The time weight that is assigned to a violation | 2 |
The description of a violation | Tires - Less than 2/32 inch tread depth |
The description of the violation group | Tires |
The unit a violation is cited against | Vehicle main unit |
The date of the inspection | 2024-03-22 |
Code of the violation | 39141A |
Name of the BASIC | Driver Fitness |
The violation is identified as Out-Of-Service violation | Y |
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation | 2 |
The severity weight that is assigned to a violation | 1 |
The time weight that is assigned to a violation | 2 |
The description of a violation | Operating a property-carrying vehicle without a valid medical certificate in possession or on file with the state drivers licensing agency. History of either fail |
The description of the violation group | Medical Certificate |
The unit a violation is cited against | Driver |
Date of last update: 25 Mar 2025
Sources: New York Secretary of State