Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-12-21
|
Emphasis |
N: TRENCH
|
Case Closed |
2016-05-11
|
Related Activity
Type |
Referral |
Activity Nr |
1048203 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260651 H01 |
Issuance Date |
2016-02-23 |
Abatement Due Date |
2016-03-02 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2016-04-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation: a) Lot 148 - On or about December 21, 2015 and at times prior thereto, employees were working in an unprotected trench between 6' and 8' in depth in order to repair a broken water line. A water pump was being used, but it was not adequate enough and water continued to accumulate. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260651 H02 |
Issuance Date |
2016-02-23 |
Abatement Due Date |
2016-03-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-04-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(h)(2): Where water was controlled or prevented from accumulating by use of water removal equipment, the water removal equipment and operations were not monitored by a competent person to ensure proper operation: a) Lot 148 - On or about December 21, 2015 and at times prior thereto, employees were working in an unprotected trench between 6' and 8' in depth in order to repair a broken water line. A water pump was being used, but it was not adequate enough nor being monitored by a competent person and water continued to accumulate. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
2016-02-23 |
Abatement Due Date |
2016-03-02 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2016-04-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions: a) Lot 148 - On or about December 21, 2015 and at times prior thereto, employees were working in an unprotected trench between 6' and 8' in depth in order to repair a broken water line. A water pump was being used, but it was not adequate enough and water continued to accumulate. There was no competent person on site to perform inspections of the trench. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2016-02-23 |
Abatement Due Date |
2016-03-02 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2016-04-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a) Lot 148 - On or about December 21, 2015 and at times prior thereto, employees were working in an unprotected trench between 6' and 8' in depth in order to repair a broken water line. A water pump was being used, but it was not adequate enough and water continued to accumulate. |
|
|