Search icon

MILL BASIN BRIDGE CONSTRUCTORS, LLC

Company Details

Name: MILL BASIN BRIDGE CONSTRUCTORS, LLC
Jurisdiction: New York
Legal type: FOREIGN LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 26 Feb 2015 (10 years ago)
Entity Number: 4717088
ZIP code: 10005
County: New York
Place of Formation: Delaware
Address: 28 LIBERTY ST, New York, NY, United States, 10005

DOS Process Agent

Name Role Address
MILL BASIN BRIDGE CONSTRUCTORS, LLC DOS Process Agent 28 LIBERTY ST, New York, NY, United States, 10005

History

Start date End date Type Value
2019-01-28 2025-02-04 Address 28 LIBERTY ST., NEW YORK, NY, 10005, USA (Type of address: Service of Process)
2015-02-26 2019-01-28 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
250204000217 2025-02-04 BIENNIAL STATEMENT 2025-02-04
230201002915 2023-02-01 BIENNIAL STATEMENT 2023-02-01
210202061375 2021-02-02 BIENNIAL STATEMENT 2021-02-01
SR-70517 2019-01-28 CERTIFICATE OF CHANGE 2019-01-28
150226000817 2015-02-26 APPLICATION OF AUTHORITY 2015-02-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342361458 0215000 2017-05-26 MILL BASIN BRIDGE BELT PARKWAY BETWEEN EXIT 13 AND EXIT 11, BROOKLYN, NY, 11234
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-05-30
Emphasis L: FALL, P: FALL, L: BRIDGE
Case Closed 2018-12-05

Related Activity

Type Referral
Activity Nr 1221119
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260020 B03
Issuance Date 2017-11-07
Abatement Due Date 2017-11-28
Current Penalty 0.0
Initial Penalty 12675.0
Contest Date 2017-12-06
Final Order 2018-12-05
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(3): Machinery, tool(s), material(s), or equipment which was not in compliance with the applicable requirement(s) of 29 CFR 1926 was not prohibited, and/or was not either identified as unsafe by tagging, or locking the controls to render them inoperable, or physically removed from its place of operation. a) Barge under new Mill Basin Bridge: An aerial lift malfunctioned and was not either identified as unsafe by tagging, or locking the controls to render it inoperable, or physically removed from its place of operation. On or about 05/26/17.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260453 B02 I
Issuance Date 2017-11-07
Abatement Due Date 2017-11-28
Current Penalty 12000.0
Initial Penalty 12675.0
Contest Date 2017-12-06
Final Order 2018-12-05
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(i): Lift controls shall be tested each day prior to use to determine that such controls are in safe working condition. a) Barge under new Mill Basin Bridge: Employees utilized an articulating boom aerial lift to install bolts on the bridge steel girders. Lift controls were not tested on the day of operation prior to use to determine that the controls were in safe working condition. On or about 05/26/17.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260502 D16 III
Issuance Date 2017-11-07
Abatement Due Date 2017-11-28
Current Penalty 0.0
Initial Penalty 12675.0
Contest Date 2017-12-06
Final Order 2018-12-05
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) Barge under new Mill Basin Bridge: Employees used personal fall arrest systems while working from an aerial lift. In an incident, one employee was thrown out of the lift basket and fell about 15 feet to the lower level. The personal fall arrest system was not rigged such that the employee could not free fall more than 6 feet nor contact any lower level. On or about 05/26/17.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260502 D21
Issuance Date 2017-11-07
Abatement Due Date 2017-11-28
Current Penalty 7000.0
Initial Penalty 12675.0
Contest Date 2017-12-06
Final Order 2018-12-05
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: a) New Mill Basin Bridge jobsite: Employees used personal fall arrest systems while working from an aerial lift. Retractable lanyards used were not inspected prior to each use. Damaged retractable lanyards were not removed from service. On or about 05/26/17.

Date of last update: 25 Mar 2025

Sources: New York Secretary of State