Name: | MILL BASIN BRIDGE CONSTRUCTORS, LLC |
Jurisdiction: | New York |
Legal type: | FOREIGN LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 26 Feb 2015 (10 years ago) |
Entity Number: | 4717088 |
ZIP code: | 10005 |
County: | New York |
Place of Formation: | Delaware |
Address: | 28 LIBERTY ST, New York, NY, United States, 10005 |
Name | Role | Address |
---|---|---|
MILL BASIN BRIDGE CONSTRUCTORS, LLC | DOS Process Agent | 28 LIBERTY ST, New York, NY, United States, 10005 |
Start date | End date | Type | Value |
---|---|---|---|
2019-01-28 | 2025-02-04 | Address | 28 LIBERTY ST., NEW YORK, NY, 10005, USA (Type of address: Service of Process) |
2015-02-26 | 2019-01-28 | Address | 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
250204000217 | 2025-02-04 | BIENNIAL STATEMENT | 2025-02-04 |
230201002915 | 2023-02-01 | BIENNIAL STATEMENT | 2023-02-01 |
210202061375 | 2021-02-02 | BIENNIAL STATEMENT | 2021-02-01 |
SR-70517 | 2019-01-28 | CERTIFICATE OF CHANGE | 2019-01-28 |
150226000817 | 2015-02-26 | APPLICATION OF AUTHORITY | 2015-02-26 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342361458 | 0215000 | 2017-05-26 | MILL BASIN BRIDGE BELT PARKWAY BETWEEN EXIT 13 AND EXIT 11, BROOKLYN, NY, 11234 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1221119 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260020 B03 |
Issuance Date | 2017-11-07 |
Abatement Due Date | 2017-11-28 |
Current Penalty | 0.0 |
Initial Penalty | 12675.0 |
Contest Date | 2017-12-06 |
Final Order | 2018-12-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(3): Machinery, tool(s), material(s), or equipment which was not in compliance with the applicable requirement(s) of 29 CFR 1926 was not prohibited, and/or was not either identified as unsafe by tagging, or locking the controls to render them inoperable, or physically removed from its place of operation. a) Barge under new Mill Basin Bridge: An aerial lift malfunctioned and was not either identified as unsafe by tagging, or locking the controls to render it inoperable, or physically removed from its place of operation. On or about 05/26/17. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 I |
Issuance Date | 2017-11-07 |
Abatement Due Date | 2017-11-28 |
Current Penalty | 12000.0 |
Initial Penalty | 12675.0 |
Contest Date | 2017-12-06 |
Final Order | 2018-12-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(i): Lift controls shall be tested each day prior to use to determine that such controls are in safe working condition. a) Barge under new Mill Basin Bridge: Employees utilized an articulating boom aerial lift to install bolts on the bridge steel girders. Lift controls were not tested on the day of operation prior to use to determine that the controls were in safe working condition. On or about 05/26/17. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260502 D16 III |
Issuance Date | 2017-11-07 |
Abatement Due Date | 2017-11-28 |
Current Penalty | 0.0 |
Initial Penalty | 12675.0 |
Contest Date | 2017-12-06 |
Final Order | 2018-12-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) Barge under new Mill Basin Bridge: Employees used personal fall arrest systems while working from an aerial lift. In an incident, one employee was thrown out of the lift basket and fell about 15 feet to the lower level. The personal fall arrest system was not rigged such that the employee could not free fall more than 6 feet nor contact any lower level. On or about 05/26/17. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260502 D21 |
Issuance Date | 2017-11-07 |
Abatement Due Date | 2017-11-28 |
Current Penalty | 7000.0 |
Initial Penalty | 12675.0 |
Contest Date | 2017-12-06 |
Final Order | 2018-12-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: a) New Mill Basin Bridge jobsite: Employees used personal fall arrest systems while working from an aerial lift. Retractable lanyards used were not inspected prior to each use. Damaged retractable lanyards were not removed from service. On or about 05/26/17. |