Search icon

XINLI CONSTRUCTION LLC

Company Details

Name: XINLI CONSTRUCTION LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 19 Mar 2015 (10 years ago)
Entity Number: 4728468
ZIP code: 11214
County: Kings
Place of Formation: New York
Address: 148 BAY 26 ST, BROOKLYN, NY, United States, 11214

DOS Process Agent

Name Role Address
JURONG CONSTRUCTION LLC DOS Process Agent 148 BAY 26 ST, BROOKLYN, NY, United States, 11214

Filings

Filing Number Date Filed Type Effective Date
150319010133 2015-03-19 ARTICLES OF ORGANIZATION 2015-03-19

Complaints

Start date End date Type Satisafaction Restitution Result
2022-11-04 2022-12-14 Non-Delivery of Service No 0.00 Advised to Sue

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344219753 0215000 2019-08-08 674 ST MARKS AVE, BROOKLYN, NY, 11216
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2019-08-08
Case Closed 2020-01-28

Related Activity

Type Inspection
Activity Nr 1254718
Safety Yes
342547189 0215000 2017-08-08 674 ST MARKS AVE, BROOKLYN, NY, 11216
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2017-08-08
Emphasis L: LOCALTARG, P: LOCALTARG

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260304 H01
Issuance Date 2018-02-05
Abatement Due Date 2018-02-09
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2019-05-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood that which shall completely enclose that portion of the saw above the table and the material being cut: a) The Rigid table saw did not have a blade guard. Employees were using the saw, were exposed to the unguarded blade. Location: 674 St Marks Ave, Brooklyn, N.Y. On or about 8/8/2017
Citation ID 01002
Citaton Type Serious
Standard Cited 19260403 I02 I
Issuance Date 2018-02-05
Abatement Due Date 2018-02-09
Current Penalty 3880.0
Initial Penalty 3880.0
Final Order 2019-05-30
Nr Instances 5
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosure: a) Live circuit breaker panels (5 instances) were not covered at the jobsite; a gut renovation of the 3 story residential building; employees were exposed to electric shock hazard. Location: 674 St Marks Ave, Brooklyn, N.Y. On or about 8/8/2017
Citation ID 01003
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2018-02-05
Abatement Due Date 2018-02-13
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2019-05-30
Nr Instances 7
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits and equipment was not permanent and continuous: a) Extension cords had broken ground pins and several cords were field made without having electric grounds connected; employees were exposed to electric shock hazard (7 instances observed). Location: 674 St Marks Ave, Brooklyn, N.Y. On or about 8/8/2017
Citation ID 01004
Citaton Type Serious
Standard Cited 19260405 A02 II E
Issuance Date 2018-02-05
Abatement Due Date 2018-02-13
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2019-05-30
Nr Instances 10
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(E): All lamps for temporary illumination were not protected from accidental contact or breakage: a) Temporary lights did not have protective cages; throughout the jobsite. Employees were exposed to electric shock and broken glass hazard. Location: 674 St Marks Ave, Brooklyn, N.Y. On or about 8/8/2017
Citation ID 01005
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2018-02-05
Abatement Due Date 2018-02-13
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2019-05-30
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with: (i) At least one handrail; and (ii) One stairrail system along each unprotected side or edge. a) The stair to the cellar did not have a stairrail; employees were exposed to trip/fall hazard when using the stair during construction activities. Location: 674 St Marks Ave, Brooklyn, N.Y. On or about 8/8/2017
Citation ID 02001
Citaton Type Other
Standard Cited 19260051 H
Issuance Date 2018-02-05
Abatement Due Date 2018-02-15
Current Penalty 311.0
Initial Penalty 311.0
Final Order 2019-05-30
Nr Instances 5
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.51(h): The employer did not keep the workplace reasonably free of rodents, insects and other vermin and maintain a continuing and effective extermination program where their presence is detected. a) Employees were exposed to rodent hazards due to insufficient pest control at the construction site, a gut renovation of the 3 story building. There were rat droppings throughout the ground floor. Location: 674 St Marks Ave, Brooklyn, N.Y. On or about 8/8/2017
Citation ID 02002A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2018-02-05
Abatement Due Date 2018-02-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-30
Nr Instances 1
Nr Exposed 3
FTA Inspection NR 1421975
FTA Issuance Date 2020-01-28
FTA Current Penalty 1500.0
FTA Final Order Date 2020-02-26
Citation text line 29 CFR 1910.1200(e)(1): When employees use or may be exposed to hazardous chemicals, products, or materials the employer did not develop, implement, and maintain at the workplace a written OSHA Hazard Communication Program: a) A written chemical Hazard Communication Program was not provided by the employer to ensure employees have information and use safety precautions for chemical products they use; employees use Garco Seal coat and other products at the jobsite, a gut renovation of 3 story residential building. Location: 674 St Marks Ave, Brooklyn, N.Y. On or about 8/8/2017
Citation ID 02002B
Citaton Type Other
Standard Cited 19101200 G01
Issuance Date 2018-02-05
Abatement Due Date 2018-02-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-30
Nr Instances 1
Nr Exposed 3
FTA Inspection NR 1421975
FTA Issuance Date 2020-01-28
FTA Current Penalty 0.0
FTA Final Order Date 2020-02-26
Citation text line 29 CFR 1910.1200(g)(1): The employer did not have material safety data sheets (MSDS sheets) for the hazardous chemicals, products, or materials employees may be exposed to in the workplace, as part of the employers Hazard Communication Program: a) Material Safety Data Sheets (MSDS) were not provided and made accessible to employees. Location: 674 St Marks Ave, Brooklyn, N.Y. On or about 8/8/2017
Citation ID 02002C
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2018-02-05
Abatement Due Date 2018-02-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-30
Nr Instances 1
Nr Exposed 3
FTA Inspection NR 1421975
FTA Issuance Date 2020-01-28
FTA Current Penalty 0.0
FTA Final Order Date 2020-02-26
Citation text line 29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training, as required by the OSHA Hazard Communication Standard, about any health and safety hazards for chemicals, products, or materials employees use or may be exposed to: a) Hazard Communication Program training was not provided to employees. Location: 674 St Marks Ave, Brooklyn, N.Y. On or about 8/8/2017