Search icon

ALLEGIANT HEALTH, LLC

Company Details

Name: ALLEGIANT HEALTH, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Inactive
Date of registration: 19 Mar 2015 (10 years ago)
Date of dissolution: 01 Nov 2017
Entity Number: 4728936
ZIP code: 12084
County: Schenectady
Place of Formation: New York
Address: PO BOX 730, GUILDERLAND, NY, United States, 12084

DOS Process Agent

Name Role Address
RACHEL M. MEGYESI DOS Process Agent PO BOX 730, GUILDERLAND, NY, United States, 12084

Filings

Filing Number Date Filed Type Effective Date
171101000211 2017-11-01 ARTICLES OF DISSOLUTION 2017-11-01
150319010448 2015-03-19 ARTICLES OF ORGANIZATION 2015-03-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347104481 0214700 2023-11-14 75 NORTH INDUSTRY COURT, DEER PARK, NY, 11729
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2023-11-14
Emphasis N: AMPUTATE
Case Closed 2024-09-09

Related Activity

Type Referral
Activity Nr 2101762
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100147 C04 II B
Issuance Date 2024-05-07
Abatement Due Date 2024-05-24
Current Penalty 6200.0
Initial Penalty 11292.0
Contest Date 2024-05-29
Final Order 2024-09-30
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a) Workplace, Production Area, Line 11 - Employees performing adjustments were exposed to hazardous energy as a result of the employer's written energy control procedures did not include machine specific procedures that contain clear and specific steps for the shut down, isolation and securing of machines such as, but not limited to an Uhlmann Blister Machine Model UPS-2MT; on or about 11/10/23. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Other
Standard Cited 19100147 C07 I
Issuance Date 2024-05-07
Abatement Due Date 2024-05-24
Current Penalty 6200.0
Initial Penalty 11292.0
Contest Date 2024-05-29
Final Order 2024-09-30
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) Workplace, Production Area, Line 11 - The employees were performing servicing on an Uhlmann Blister Machine Model UPS-2MT without having received adequate instruction on the safe application, usage, and removal of the electrical and mechanical energy controls are acquired by employees; on or about 11/10/23. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.

Date of last update: 08 Mar 2025

Sources: New York Secretary of State