OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343973459 0215000 2019-05-01 7 HASTINGS STREET, BROOKLYN, NY, 11235
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-05-01
Emphasis L: FALL, L: GUTREH, P: FALL
Case Closed 2024-12-18

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2019-10-29
Abatement Due Date 2019-11-04
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-11-27
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. Location: 7 Hastings Street, Brooklyn, NY. On or about 5/1/2019, a) Protective footwear were not being worn by employees working in a construction site.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2019-10-29
Abatement Due Date 2019-11-06
Current Penalty 3410.0
Initial Penalty 3410.0
Final Order 2019-11-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use. Location: 7 Hastings Street, Brooklyn, NY. On or about 5/1/2019, a) An handheld angle grinder was used without the blade guard installed.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260304 I01
Issuance Date 2019-10-29
Abatement Due Date 2019-11-04
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2019-11-27
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(i)(1): Each circular hand-fed rip saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut. Location: 7 Hastings Street, Brooklyn, NY. On or about 5/1/2019, a) A 10 inch table saw was used without the blade guard installed. Approximately 4 inches of the blade was raised above the table.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2019-10-29
Abatement Due Date 2019-11-06
Current Penalty 2273.0
Initial Penalty 2273.0
Final Order 2019-11-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. Location: 7 Hastings Street, Brooklyn, NY. On or about 5/1/2019, a) An energized duplex outlet box was being used and was not without mounted. The outlet box was on the ground in an active work area.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260405 B02
Issuance Date 2019-10-29
Abatement Due Date 2019-11-04
Current Penalty 2273.0
Initial Penalty 2273.0
Final Order 2019-11-27
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(b)(2): In an energized installation, each outlet box did not have a cover, faceplate, or fixture canopy. Location: 7 Hastings Street, Brooklyn, NY. On or about 5/1/2019, a) An energized outlet box being used by employees was not installed with faceplate.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260416 E01
Issuance Date 2019-10-29
Abatement Due Date 2019-11-06
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-11-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used. Location: 7 Hastings Street, Brooklyn, NY. On or about 5/1/2019, a) The outer jacket of an extension cord used by employee onsite was frayed.
Citation ID 01007
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2019-10-29
Abatement Due Date 2019-11-04
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2019-11-27
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: 7 Hastings Street, Brooklyn, NY. On or about 5/1/2019, a) An employee working from the 3rd floor balcony was not protected from a fall.
Citation ID 01008
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2019-10-29
Abatement Due Date 2019-11-04
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-11-27
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair rail system along each unprotected side or edge. Location: 7 Hastings Street, Brooklyn, NY. On or about 5/1/2019, a) An unprotected side of the stairway leading from the ground floor to the 2nd floor did not have any stair rail.
Citation ID 01009
Citaton Type Serious
Standard Cited 19261053 B18
Issuance Date 2019-10-29
Abatement Due Date 2019-11-06
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-11-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(18): Ladder repairs did not restore the ladder to a condition meeting its original design criteria, before the ladder was returned to use. Location: 7 Hastings Street, Brooklyn, NY. On or about 5/1/2019, a) Employee used a defective step ladder to install cement boards to the ceiling. The legs were broken and a spreader was missing.