Search icon

LOLSONS, LLC

Company Details

Name: LOLSONS, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 26 Mar 2015 (10 years ago)
Entity Number: 4732281
ZIP code: 11949
County: Suffolk
Place of Formation: New York
Address: 4 CARA COURT, MANORVILLE, NY, United States, 11949

DOS Process Agent

Name Role Address
ARTHUR ABBATE DOS Process Agent 4 CARA COURT, MANORVILLE, NY, United States, 11949

Filings

Filing Number Date Filed Type Effective Date
150326000409 2015-03-26 ARTICLES OF ORGANIZATION 2015-03-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340887546 0214700 2015-08-31 14 PENNIMAN POINT ROAD, QUOGUE, NY, 11959
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-08-31
Emphasis L: FALL
Case Closed 2017-03-02

Related Activity

Type Referral
Activity Nr 1015679
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 A01
Issuance Date 2016-01-13
Abatement Due Date 2016-01-20
Current Penalty 2000.0
Initial Penalty 2520.0
Final Order 2016-02-10
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it: Note: Exceptions are provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section. a) Worksite, 14 Penniman Point Road, Quogue NY: Employees were standing on a makeshift scaffold that was unable to support its load. The scaffold collapsed with the employees causing them to fall approximately 11.6 ft to the ground; on or about 8/31/15. NOTE: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2016-01-13
Abatement Due Date 2016-01-20
Current Penalty 2000.0
Initial Penalty 2520.0
Final Order 2016-02-10
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) Worksite, 14 Penniman Point Road, Quogue, NY: Employees constructing a roof addition were standing on a makeshift scaffold platform that was measured at approximately 9 inches; on or about 8/31/15. NOTE: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2016-01-13
Abatement Due Date 2016-02-02
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2016-02-10
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) Worksite, 14 Penniman Point Road, Quogue, NY: Employees constructing a roof addition were using a makeshift scaffold not designed by a competent person; on or about 8/31/15. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2016-01-13
Abatement Due Date 2016-01-20
Current Penalty 2000.0
Initial Penalty 2520.0
Final Order 2016-02-10
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite, 14 Penniman Point Rd, Quogue, NY: Employees were working on a makeshift scaffold at approximately 11.6 feet off the ground without fall protection; on or about 8/31/15. NOTE: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.

Date of last update: 25 Mar 2025

Sources: New York Secretary of State