Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-02-07
|
Emphasis |
L: FALL
|
Case Closed |
2019-11-19
|
Related Activity
Type |
Referral |
Activity Nr |
1424861 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2019-08-01 |
Current Penalty |
3200.0 |
Initial Penalty |
5304.0 |
Final Order |
2019-10-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports. Location: 480 Broadway, New York, NY. Broome Street Façade. a) Employees were painting the fire escape while standing on the second platform of the tubular welded frame scaffold that was not fully planked. On or about 02/07/2019. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2019-08-01 |
Abatement Due Date |
2019-08-09 |
Current Penalty |
2100.0 |
Initial Penalty |
3789.0 |
Final Order |
2019-10-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Location: 480 Broadway, New York, NY. Broome Street Façade. a) A competent person did not inspect the scaffold after it was erected. The 11 feet high tubular welded frame had missing planks, and fall protection was not provided. On or about 02/07/2019. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2019-08-01 |
Abatement Due Date |
2019-08-07 |
Current Penalty |
3200.0 |
Initial Penalty |
5304.0 |
Final Order |
2019-10-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: 480 Broadway, New York, NY. Broome Street Façade. a) Employees worked from tubular welded frame scaffold 11 feet high were not protected from falling to concrete floor by the use of fall protection systems. On or about 02/07/2019. |
|
|