Search icon

VESCOM SYSTEMS, LLC

Company Details

Name: VESCOM SYSTEMS, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 13 Apr 2015 (10 years ago)
Entity Number: 4740879
ZIP code: 07032
County: New York
Place of Formation: New York
Address: 100 THIRD AVENUE, KEARNY, NJ, United States, 07032

DOS Process Agent

Name Role Address
C/O STANLEY STERNCHOS AND ERNEST TEITELBAUM DOS Process Agent 100 THIRD AVENUE, KEARNY, NJ, United States, 07032

History

Start date End date Type Value
2015-04-13 2018-11-13 Address 99 WASHINGTON AVE, SUITE 1008, ALBANY, NY, 12260, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
181113000317 2018-11-13 CERTIFICATE OF CHANGE 2018-11-13
150722000994 2015-07-22 CERTIFICATE OF PUBLICATION 2015-07-22
150413010095 2015-04-13 ARTICLES OF ORGANIZATION 2015-04-13

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345631097 0215000 2021-11-10 859 MYRTLE AVE., BROOKLYN, NY, 11206
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2021-11-10
Case Closed 2021-11-22

Related Activity

Type Inspection
Activity Nr 1361725
Safety Yes
343617254 0215000 2018-11-21 859 MYRTLE AVE., BROOKLYN, NY, 11206
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2018-11-21
Emphasis N: SVEP

Related Activity

Type Accident
Activity Nr 1403027

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260602 C01 II
Issuance Date 2019-05-20
Abatement Due Date 2019-05-31
Current Penalty 10210.0
Initial Penalty 10210.0
Contest Date 2019-05-28
Final Order 2020-07-06
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(c)(1)(ii): Modifications or additions which affect the capacity or safe operation of the equipment were made without the manufacturer's written approval. a) 4th floor: A forklift stacker was used with a shorty lift boom attached to the fork blades for moving and installing wall panels. But the capacity, operation, and maintenance instruction plates, tags, or decals were not changed before using the affected forklift. The addition of using a lift boom affects the lift capacity and safe operation of the forklift stacker, and the lift boom was used without the forklift stacker manufacturer's written approval. On or about 11/21/18.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260602 C01 VI
Issuance Date 2019-05-20
Abatement Due Date 2019-05-28
Current Penalty 10210.0
Initial Penalty 10210.0
Contest Date 2019-05-28
Final Order 2020-07-06
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(c)(1)(vi): Industrial truck(s) in use did not meet the applicable requirements of design, construction, stability, inspection, testing, maintenance, and operation, as defined in American National Standards Institute B56.1-1969, Safety Standards for Powered Industrial Trucks. a) 4th floor: A forklift stacker was used with a shorty lift boom attached to the fork blades for moving and installing wall panels. Employees operated the forklift in high wind condition to lift a panel that is about 15 feet by 10 feet. The forklift overturned and the wall panel toppled on top of an employee during panel lifting under these conditions. On or about 11/21/18.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260602 C01 VII
Issuance Date 2019-05-20
Abatement Due Date 2019-05-28
Current Penalty 10210.0
Initial Penalty 10210.0
Contest Date 2019-05-28
Final Order 2020-07-06
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(c)(1)(vii): A safe place to ride forklift trucks was not provided where riding of trucks is authorized. a) 4th floor: A forklift stacker was used with a shorty lift boom attached to the fork blades for moving and installing wall panels. An employee was instructed to ride on the forklift stacker to act as additional counterweight for lifting the panel walls. A safe place to ride the forklift stacker was not provided, and the employee was thrown off the forklift when it overturned while lifting a wall panel. On or about 11/21/18.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260602 D
Issuance Date 2019-05-20
Abatement Due Date 2019-05-31
Current Penalty 10210.0
Initial Penalty 10210.0
Contest Date 2019-05-28
Final Order 2020-07-06
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(d): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l), as referenced to 29 CFR 1910.178(l)(1)(i). Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178. a) 4th floor: A forklift stacker was used with a shorty lift boom attached to the fork blades for moving and installing wall panels. The employer did not evaluate, train, test, or certify the forklift stacker operator to ensure that he is competent to operate a forklift stacker safely. On or about 11/21/18.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260760 D01
Issuance Date 2019-05-20
Abatement Due Date 2019-05-28
Current Penalty 10210.0
Initial Penalty 10210.0
Contest Date 2019-05-28
Final Order 2020-07-06
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(d)(1): Personal fall arrest systems, positioning device systems and their components were not conform to the criteria in �� 1926.502 (see Appendix G to this subpart). a) 4th floor: Employees were installing wall panels at the edge of the building. One employee was tied off to a wall panel lying on the floor as a fall arrest anchor while removing guardrails from the edge of the building. The wall panel on the floor was not structurally secured and was not conform to the criteria of a fall arrest anchor. On or about 11/21/18.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260760 A01
Issuance Date 2019-05-20
Abatement Due Date 2019-05-28
Current Penalty 20420.0
Initial Penalty 20420.0
Contest Date 2019-05-28
Final Order 2020-07-06
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who was on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. a) 4th floor: Employee were installing wall panels at the edge of the building without fall protection. Guardrails were removed from the edge of the building and employees were not tied off to fall arrest anchors during the installation process. On or about 11/21/18. Vescom Systems, LLC was previously cited for a violation of an equivalent Occupational Safety and Health Standard 29 CFR 1926.501(b)(1), which was contained in OSHA inspection number 1200138, citation number 1, item number 2 and was affirmed as a final order on 04/18/17, with respect to a workplace located at Villa BXV Kensington & Sagamore Rd, Bronxville, NY 10708.
342001385 0216000 2016-12-27 VILLA BXV KENSINGTON & SAGAMORE RD, BRONXVILLE, NY, 10708
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-12-27
Emphasis L: FALL
Case Closed 2019-07-22

Related Activity

Type Complaint
Activity Nr 1168924
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2017-03-13
Current Penalty 5070.0
Initial Penalty 5070.0
Final Order 2017-04-18
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: On or about: 12/27/16 Location: Villa BXV new residences construction at 23 Kensington Ter, Bronxville, NY 10708 a) Two employees engaged in residential construction activities, installing sheathings at a roof level approximately 15 feet above the ground were not protected from struck by hazards while not wearing hard hats. They had access to the roof through the second floor of a four story building located next, which is also part of the construction project and during that day construction activities were observed at the upper floor levels.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2017-03-13
Current Penalty 6338.0
Initial Penalty 6338.0
Final Order 2017-04-18
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about: 12/27/16 Location: Villa BXV new residences construction at 23 Kensington Ter, Bronxville, NY 10708 a) Two employees engaged in residential construction activities, installing sheathings at a roof level approximately 15 feet above the ground were not protected from falling hazard by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Date of last update: 25 Mar 2025

Sources: New York Secretary of State