Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-04-25
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2016-08-26
|
Related Activity
Type |
Referral |
Activity Nr |
1084581 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260095 A |
Issuance Date |
2016-05-31 |
Abatement Due Date |
2016-06-10 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-06-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: a) On or about April 25, 2016- job site at 245-60 61st Ave, Douglaston, NY 11362 an employee was using a hand held grinder to cut and finish material without wearing protective glasses. WRITTEN ABATEMENT CERTIFICATION IS NEEDED. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2016-05-31 |
Abatement Due Date |
2016-06-10 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-06-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) On or about April 25, 2016- job site at 245-60 61st Ave, Douglaston, NY 11362 an employee was using a hand held grinder to cut and finish material, that had its blade guard removed. WRITTEN ABATEMENT CERTIFICATION IS NEEDED. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 II |
Issuance Date |
2016-05-31 |
Abatement Due Date |
2016-06-10 |
Current Penalty |
1600.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-06-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a) On or about April 25, 2016- job site at 245-60 61st Ave, Douglaston, NY 11362 an employee was working on a tubular welded frame scaffold that was not fully decked at the work level. WRITTEN ABATEMENT CERTIFICATION IS NEEDED. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2016-05-31 |
Abatement Due Date |
2016-06-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about April 25, 2016- job site at 245-60 61st Ave, Douglaston, NY 11362 an employee was working on a tubular welded frame scaffold that did not have base plates or mud sills. WRITTEN ABATEMENT CERTIFICATION IS NEEDED. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2016-05-31 |
Abatement Due Date |
2016-06-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) On or about April 25, 2016- job site at 245-60 61st Ave, Douglaston, NY 11362 an employee was working on a tubular welded frame scaffold that did not have an access ladder and the employee had to climb the frame to get to the work level. WRITTEN ABATEMENT CERTIFICATION IS NEEDED. |
|
Citation ID |
01003D |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2016-05-31 |
Abatement Due Date |
2016-06-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) On or about April 25, 2016- job site at 245-60 61st Ave, Douglaston, NY 11362 an employee was working on a tubular welded frame scaffold approximately 12 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS NEEDED. |
|
|