Search icon

REDNELO'S BUILDERS LLC

Company Details

Name: REDNELO'S BUILDERS LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 16 Apr 2015 (10 years ago)
Entity Number: 4742999
ZIP code: 13084
County: Onondaga
Place of Formation: New York
Address: 2386 ROUTE 11A, LAFAYETTE, NY, United States, 13084

Agent

Name Role Address
JASON OLENDER Agent 2386 ROUTE 11A, LAFAYETTE, NY, 13084

DOS Process Agent

Name Role Address
JASON OLENDER DOS Process Agent 2386 ROUTE 11A, LAFAYETTE, NY, United States, 13084

Filings

Filing Number Date Filed Type Effective Date
150416010078 2015-04-16 ARTICLES OF ORGANIZATION 2015-04-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340700103 0215800 2015-06-11 FAIRFIELD INN, 71 N. GENESEE STREET, UTICA, NY, 13502
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2015-06-11
Emphasis L: LOCALTARG
Case Closed 2019-10-29

Related Activity

Type Inspection
Activity Nr 1070033
Safety Yes
Type Inspection
Activity Nr 1069984
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260028 A
Issuance Date 2015-08-05
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2015-09-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions: a) Southeast corner of building, on or about 6-11-15: One employee was working directly below another employee, without head protection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2015-08-05
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-09-25
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) East end of roof, on or about 6-11-15: One employee was working on a flat roof with unprotected sides and edges, and was not protected from falls, exposing the employee to a fall hazard of 36 feet 4 inches.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2015-08-05
Abatement Due Date 2015-08-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) East end of roof, on or about 6-11-15: One employee was working on a flat roof with unprotected sides and edges, without the training necessary for the employee to recognize the hazards associated with falls and his work, exposing the employee to fall hazard of 36 feet 4 inches. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Citation ID 01003
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2015-08-05
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-09-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: a) Southeast corner of building, on or about 6-11-15: One employee was working in an articulating, extensible boom, aerial lift, without a safety harness or body belt properly connected, exposing the employee to a fall hazard of 36 feet.
Citation ID 02001
Citaton Type Other
Standard Cited 19030019 C01
Issuance Date 2015-12-11
Abatement Due Date 2015-12-31
Current Penalty 400.0
Initial Penalty 400.0
Final Order 2016-01-12
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) 71 N. Genesee Street, Utica, NY, on or about 12/10/2015: The employer did not provide abatement certification for Citation 01, Item 002b issued on August 5, 2015. An abatement demand letter was sent to the employer on November 13, 2015. Abatement documentation is required for this item.
339865669 0213100 2014-07-24 84 SISSON RD, SOUTH GLENS FALLS, NY, 12803
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2014-07-24
Emphasis L: FALL
Case Closed 2015-09-12

Related Activity

Type Inspection
Activity Nr 986548
Safety Yes
Type Inspection
Activity Nr 986580
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2014-08-28
Abatement Due Date 2014-09-08
Current Penalty 1200.0
Initial Penalty 1600.0
Final Order 2014-10-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) On or about July 25, 2014 and at times prior thereto at 24 Sand Hill; the employers subcontractor had an employee using a pneumatic nail gun without the use of eye protection.
Citation ID 01002
Citaton Type Other
Standard Cited 19260501 B13
Issuance Date 2014-08-28
Abatement Due Date 2014-09-08
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2014-10-15
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about July 25, 2014 and at times prior thereto at 24 Sand Hill; the employers subcontractors employees were exposed to an approximately 20' fall hazard without the use of fall protection.
339506768 0213600 2013-12-02 2299 BRIGHTON HENRIETTA TOWNLINE ROAD, ROCHESTER, NY, 14623
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2013-12-02
Emphasis N: CTARGET, P: CTARGET
Case Closed 2015-09-08

Related Activity

Type Inspection
Activity Nr 950624
Safety Yes
Type Inspection
Activity Nr 950702
Safety Yes
Type Inspection
Activity Nr 950717
Safety Yes
Type Inspection
Activity Nr 950898
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260152 A01
Issuance Date 2014-01-09
Current Penalty 3150.0
Initial Penalty 3150.0
Final Order 2014-02-04
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.152(a)(1): Containers and portable tanks used for the storage and handling of flammable liquids were not approved: (a) On or about 12/02/13, at the Ethan Pointe Apartment Homes, located at 2299 Brighton Henrietta Town Line Road in Rochester, New York a dispensing tank containing diesel fuel, was not an approved container for flammable liquids. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260152 E04
Issuance Date 2014-01-09
Current Penalty 1890.0
Initial Penalty 1890.0
Final Order 2014-02-04
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.152(e)(4): Units dispensing flammable or combustible liquids were not protected against collision damage: (a) On or about 12/02/13, at the Ethan Pointe Apartment Homes, located at 2299 Brighton Henrietta Town Line Road in Rochester, New York, a portable tank dispenser with a liquid capacity of 100 US gallons was placed near an access to a holding area where trucks and forklifts travel frequently (10 times a day) to retrieve materials. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-01-09
Current Penalty 2520.0
Initial Penalty 2520.0
Final Order 2014-02-04
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) On or about 12/02/13, at the Ethan Pointe Apartment Homes, located at 2299 Brighton Henrietta Town Line Road in Rochester, New York, an A-Frame portable ladder, used to access an upper landing 8 feet in elevation, did not extend three feet above the landing being accessed. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261053 B13
Issuance Date 2014-01-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-04
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: (a) On or about 12/02/13, at the Ethan Pointe Apartment Homes, located at 2299 Brighton Henrietta Town Line Road in Rochester, New York, employees were accessing A-Frame step ladder. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19260151 A03
Issuance Date 2014-01-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-04
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.151(a)(3): The vicinity of operations which constituted a fire hazard were not conspicuously posted: No Smoking Or Open Flame: (a) On or about 12/02/13, at the Ethan Pointe Apartment Homes, located at 2299 Brighton Henrietta Town Line Road in Rochester, New York, a "No Smoking" was not posted at or near the fuel (diesel) dispensing tank having a fuel capacity of 100 US gallons. NO ABATEMENT CERTIFICATION REQUIRED
339196610 0215800 2013-07-11 BUCKLEY RD, SYRACUSE, NY, 13201
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-07-11
Emphasis P: FALL, L: FALL
Case Closed 2013-09-26

Date of last update: 25 Mar 2025

Sources: New York Secretary of State