347886566
|
0215000
|
2024-11-18
|
125 W 57TH STREET, NEW YORK, NY, 10019
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-11-18
|
Related Activity
Type |
Referral |
Activity Nr |
2234473 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1789711 |
Safety |
Yes |
|
|
347808750
|
0215000
|
2024-10-10
|
2035 5TH AVENUE, NEW YORK, NY, 10035
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-10-10
|
Emphasis |
P: LOCALTARG, L: LOCALTARG
|
Related Activity
Type |
Inspection |
Activity Nr |
1780876 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1780871 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1780877 |
Safety |
Yes |
|
|
347293011
|
0215600
|
2024-02-20
|
35-15 19TH AVE, ASTORIA, NY, 11105
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-02-20
|
Emphasis |
N: FALL
|
Related Activity
Type |
Referral |
Activity Nr |
2133302 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2024-07-15 |
Abatement Due Date |
2024-07-18 |
Current Penalty |
12445.0 |
Initial Penalty |
12445.0 |
Final Order |
2024-08-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a). on or about 02/20/24, on the top of A.C unit of 35-15 19th Ave. Astoria, NY An employee was working/walking on an unprotected edge of an A.C. unit on the 7th floor and fell approximately 12 ft. to the floor. |
|
|
343355590
|
0215000
|
2018-07-31
|
130 WILLIAM ST., NEW YORK, NY, 10038
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-07-31
|
Case Closed |
2019-01-18
|
Related Activity
Type |
Inspection |
Activity Nr |
1334790 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1335544 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1334962 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1335113 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1335371 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1335551 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1335091 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1335524 |
Safety |
Yes |
|
|
341119386
|
0215000
|
2015-12-14
|
133 GREENWICH STREET, NEW YORK, NY, 10006
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-12-14
|
Case Closed |
2016-06-28
|
Related Activity
Type |
Referral |
Activity Nr |
1046049 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1112005 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260028 A |
Issuance Date |
2016-06-03 |
Abatement Due Date |
2016-06-15 |
Current Penalty |
4700.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-06-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: Location: 133 Greenwich Street, New York, NY. 28th Floor. Employee was installing a side plate on the end cap of a live buss duct and appropriate personal protective equipment was not worn. On or about 12/14/2015. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260416 A01 |
Issuance Date |
2016-06-03 |
Abatement Due Date |
2016-06-15 |
Current Penalty |
4775.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-06-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means. Location: 133 Greenwich Street, New York, NY. 28th Floor. Employee was installing a side plate on the end cap of a live buss duct without de-energizing the duct or by other means. An arc blast occurred between the phases and ground of the duct.. On or about 12/14/2015. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260416 A03 |
Issuance Date |
2016-06-03 |
Abatement Due Date |
2016-06-15 |
Current Penalty |
4700.0 |
Initial Penalty |
6300.0 |
Final Order |
2016-06-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit. Location: 133 Greenwich Street, New York, NY. The employer did not ascertain if the work being done on an energized circuit could be contacted by the tasks being completed. On or about 12/14/2015. |
|
|
313790388
|
0215000
|
2009-09-15
|
236 LIVINGSTON STREET, BROOKLYN, NY, 11201
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2009-09-15
|
Case Closed |
2010-04-02
|
Related Activity
Type |
Complaint |
Activity Nr |
207397290 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260034 A |
Issuance Date |
2009-09-30 |
Abatement Due Date |
2009-10-08 |
Current Penalty |
2000.0 |
Initial Penalty |
3000.0 |
Contest Date |
2009-10-08 |
Final Order |
2010-02-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
|
|
312520257
|
0215000
|
2008-09-29
|
301 EAST 33RD STREET, NEW YORK, NY, 10016
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2008-09-29
|
Case Closed |
2009-03-23
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260403 I02 I |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-11 |
Current Penalty |
1050.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2009-03-06 |
Abatement Due Date |
2009-03-18 |
Current Penalty |
1050.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
|
309642254
|
0215000
|
2006-01-11
|
353 4TH AVENUE, BROOKLYN, NY, 11215
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2006-01-24
|
Case Closed |
2006-07-14
|
Related Activity
Type |
Referral |
Activity Nr |
202645685 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2006-01-25 |
Abatement Due Date |
2006-01-31 |
Current Penalty |
1500.0 |
Initial Penalty |
2500.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260403 I02 I |
Issuance Date |
2006-01-25 |
Abatement Due Date |
2006-01-31 |
Current Penalty |
1500.0 |
Initial Penalty |
2500.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
10 |
|
|