Search icon

ALPINE SIDING LLC

Company Details

Name: ALPINE SIDING LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 17 Apr 2015 (10 years ago)
Entity Number: 4743726
ZIP code: 14202
County: Erie
Place of Formation: New York
Address: 37 FRANKLIN STREET, SUITE 750, BUFFALO, NY, United States, 14202

Agent

Name Role Address
MATTHEW LAZROE, ESQ. Agent 37 FRANKLIN STREET, SUITE 750, BUFFALO, NY, 14202

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 37 FRANKLIN STREET, SUITE 750, BUFFALO, NY, United States, 14202

Filings

Filing Number Date Filed Type Effective Date
150417000258 2015-04-17 ARTICLES OF ORGANIZATION 2015-04-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345830152 0213600 2022-03-09 2489 FIX ROAD, GRAND ISLAND, NY, 14072
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-03-09
Emphasis L: FALL, P: FALL
Case Closed 2024-09-30

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260452 K04
Issuance Date 2022-06-02
Current Penalty 1585.0
Initial Penalty 1585.0
Final Order 2022-07-01
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(k)(4): Ladders used to support ladder jacks were not placed, fastened, or equipped with devices to prevent slipping: a) On or about 3/9/2022, at the outside area of the site, Clarence, NY. Ladder jack scaffolds were constructed by the combination of extension ladder and step ladder, and the step ladder was freestanding on rough grades that were not stable and level. The step ladder was not placed, fastened, or equipped with devices to prevent slipping. Employee was exposed to fall of 6 feet. NO ABATEMENT CERTIFICATION REQUIRED
339003550 0213600 2013-04-04 48 STERLING PLACE, LANCASTER, NY, 14086
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-04-04
Emphasis L: FALL, P: FALL
Case Closed 2013-11-06

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-05-02
Current Penalty 200.0
Initial Penalty 1600.0
Contest Date 2013-05-31
Final Order 2013-08-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: a) On or about 4/4/13 at a residential new-build located at 48 Sterling Place, Lancaster, New York; employees were using a ladder jack scaffold, with the scaffold brackets and platform to the outside of the supporting ladders, to install underlayment and shingles on the roof of a 2 story house. The employees had to access the platform by climbing the supporting ladders and climbing around the bracket and platform. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 I
Issuance Date 2013-05-02
Current Penalty 200.0
Initial Penalty 1600.0
Contest Date 2013-05-31
Final Order 2013-08-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 4/4/13 at a residential new-build located at 48 Sterling Place, Lancaster, New York; employees were installing underlayment and shingles on the roof of a 2 story house using a ladder jack scaffold. There was no personal fall arrest system in use. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2013-05-02
Current Penalty 200.0
Initial Penalty 1600.0
Contest Date 2013-05-31
Final Order 2013-08-29
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 4/4/13 at a residential new-build located at 48 Sterling Place, Lancaster, New York; employees were installing underlayment and shingles on the roof of a 2 story house with an 8 in 12 pitch. The was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
1612527210 2020-04-15 0296 PPP 5855 Pearl Street, Sanborn, NY, 14132
Loan Status Date 2021-08-06
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 8317
Loan Approval Amount (current) 8317
Undisbursed Amount 0
Franchise Name -
Lender Location ID 46391
Servicing Lender Name Manufacturers and Traders Trust Company
Servicing Lender Address One M & T Plaza, 15th Fl, BUFFALO, NY, 14203
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Sanborn, NIAGARA, NY, 14132-0171
Project Congressional District NY-26
Number of Employees 2
NAICS code 238170
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Limited Liability Company(LLC)
Originating Lender ID 46391
Originating Lender Name Manufacturers and Traders Trust Company
Originating Lender Address BUFFALO, NY
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 8416.35
Forgiveness Paid Date 2021-07-02

Date of last update: 08 Mar 2025

Sources: New York Secretary of State