Search icon

MUSHKA HANDY INC.

Company Details

Name: MUSHKA HANDY INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 20 Apr 2015 (10 years ago)
Entity Number: 4744641
ZIP code: 10038
County: Kings
Place of Formation: New York
Address: 1 MAIDEN LANE, 5TH FLOOR, NEW YORK, NY, United States, 10038

Shares Details

Shares issued 20000

Share Par Value 1

Type PAR VALUE

DOS Process Agent

Name Role Address
SPIEGEL & UTRERA, P.A., P.C. DOS Process Agent 1 MAIDEN LANE, 5TH FLOOR, NEW YORK, NY, United States, 10038

Agent

Name Role Address
SPIEGEL & UTRERA, P.A., P.C. Agent 1 MAIDEN LANE, 5TH FLOOR, NEW YORK, NY, 10038

History

Start date End date Type Value
2015-04-20 2024-04-10 Shares Share type: PAR VALUE, Number of shares: 20000, Par value: 1

Filings

Filing Number Date Filed Type Effective Date
150420000395 2015-04-20 CERTIFICATE OF INCORPORATION 2015-04-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340900471 0215600 2015-09-08 82-30 SURREY PLACE, JAMAICA, NY, 11432
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-09-08
Emphasis L: FALL
Case Closed 2016-09-29

Related Activity

Type Inspection
Activity Nr 1090977
Safety Yes
Type Referral
Activity Nr 1017352
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 B01 I
Issuance Date 2015-09-22
Abatement Due Date 2015-10-02
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2015-10-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(1)(i): Suitability for installation and use in conformity with the provisions of this subpart. Suitability of equipment for an identified purpose may be evidenced by listing, labeling, or certification for that identified purpose: a) On or about September 8, 2015- job site at 82-30 Surrey Place, Jamaica, NY 11432 the employer permitted employees to use a re-locatable power strip, designed for home usage, to power a portable cement mixer. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260405 A02 II J
Issuance Date 2015-09-22
Abatement Due Date 2015-10-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-10-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not designed for hard or extra-hard usage: a) On or about September 8, 2015- job site at 82-30 Surrey Place, Jamaica, NY 11432 the employer permitted employees to use a flexible cord set that is not designed for construction usage to power a portable cement mixer. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B01 II
Issuance Date 2015-09-22
Abatement Due Date 2015-10-02
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2015-10-07
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a) On or about September 8, 2015- job site at 82-30 Surrey Place, Jamaica, NY 11432 the employer permitted employees to work on a tubular welded frame scaffold that was not fully planked. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2015-09-22
Abatement Due Date 2015-10-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-10-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) On or about September 8, 2015- job site at 82-30 Surrey Place, Jamaica, NY 11432 the employer permitted employees to work on a tubular welded frame scaffold that had its footing placed on stacked cinder blocks. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2015-09-22
Abatement Due Date 2015-10-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-10-07
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) On or about September 8, 2015- job site at 82-30 Surrey Place, Jamaica, NY 11432 the employer permitted employees to work on a tubular welded frame scaffold approximately 30 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-09-22
Abatement Due Date 2015-10-02
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2015-10-07
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about September 8, 2015- job site at 82-30 Surrey Place, Jamaica, NY 11432 the employer permitted employees to work approximately 10 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.

Date of last update: 25 Mar 2025

Sources: New York Secretary of State