342352994
|
0215000
|
2017-05-23
|
91 LEONARD ST., NEW YORK, NY, 10001
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-05-23
|
Emphasis |
L: FALL, L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2019-05-16
|
Related Activity
Type |
Inspection |
Activity Nr |
1235287 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1235295 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2017-08-04 |
Current Penalty |
2173.0 |
Initial Penalty |
2173.0 |
Contest Date |
2017-08-22 |
Final Order |
2017-12-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: (a) Ground floor, Leonard St. entrance area: : On or about 05/23/2017, an establishment employee tying rebar was exposed hazards when using portable A frame step ladder. The ladder was used in the closed position and leaned against the wall, exposing the employee to a potential fall to the concrete floor below. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2017-08-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2017-08-22 |
Final Order |
2017-12-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Ground floor, Leonard St. entrance area: On or about 05/23/2017, an establishment employee tying rebar was exposed hazards when using portable A frame step ladder. The employee was standing on the top and top step of the ladder, exposing him to a potential fall to the concrete floor below. |
|
|
341260719
|
0215600
|
2016-02-18
|
40-22 COLLEGE POINT BLVD, FLUSHING, NY, 11354
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-02-18
|
Case Closed |
2016-12-20
|
Related Activity
Type |
Referral |
Activity Nr |
1064188 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260703 B03 |
Issuance Date |
2016-04-05 |
Abatement Due Date |
2016-04-15 |
Current Penalty |
4900.0 |
Initial Penalty |
4900.0 |
Contest Date |
2016-04-27 |
Final Order |
2016-11-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.703(b)(3): Erected shoring equipment was not inspected immediately prior to, during, and immediately after concrete placement: On or about February 18, 2016- job site at 40-22 College Point Blvd, Flushing, NY 11354 employees were working in the immediate vicinity of concrete shoring equipment that was not inspected after concrete placement. WRITTEN ABATEMENT DOCUMENTAION IS REQUIRED. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260703 B06 |
Issuance Date |
2016-04-05 |
Abatement Due Date |
2016-04-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2016-04-27 |
Final Order |
2016-11-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.703(b)(6): Base plates, shore heads, extension devices, and adjustment screws were not in firm contact, and secured when necessary, with the foundation and the form: On or about February 18, 2016- job site at 40-22 College Point Blvd, Flushing, NY 11354 employees were working in the immediate vicinity of concrete shoring equipment that did not have the shore head and base plate secured. WRITTEN ABATEMENT DOCUMENTAION IS REQUIRED. |
|
|