Search icon

IT'S ELECTRIC OF LONG ISLAND, INC.

Company Details

Name: IT'S ELECTRIC OF LONG ISLAND, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 06 Jul 2015 (10 years ago)
Entity Number: 4785016
ZIP code: 11784
County: Suffolk
Place of Formation: New York
Address: 35 SPRUCE STREET, SELDEN, NY, United States, 11784

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 35 SPRUCE STREET, SELDEN, NY, United States, 11784

Filings

Filing Number Date Filed Type Effective Date
150706010228 2015-07-06 CERTIFICATE OF INCORPORATION 2015-07-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346742992 0214700 2023-06-02 8 NYACK DRIVE, EAST NORTHPORT, NY, 11731
Inspection Type Fat/Cat
Scope Partial
Safety/Health Safety
Close Conference 2023-06-02

Related Activity

Type Accident
Activity Nr 2037500
Type Inspection
Activity Nr 1674654
Safety Yes
Type Inspection
Activity Nr 1674650
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2023-11-13
Abatement Due Date 2023-11-21
Current Penalty 1890.0
Initial Penalty 4688.0
Contest Date 2023-11-30
Final Order 2024-08-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - The employee was working on a scaffold with energized wires from the service drop for 240 VAC 200 AMP service to a residential home and was not trained properly to recognize the associated electrical hazards; on or about 06/1/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2023-11-13
Abatement Due Date 2023-11-21
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-11-30
Final Order 2024-08-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - The employee was performing electrical work on a scaffold and was not trained properly to recognize the hazards associated with the type of scaffold being used and to understand the procedure to control or minimize those hazards; on or about 06/1/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260416 A01
Issuance Date 2023-11-13
Abatement Due Date 2023-11-17
Current Penalty 1875.0
Initial Penalty 4688.0
Contest Date 2023-11-30
Final Order 2024-08-16
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(a)(1): The employer permitted the employee to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work: a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - The employee was exposed to electrical hazards while connecting energized wires from the service drop for 240 VAC 200 Amp service to a residential home; on or about 06/1/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 B05 II
Issuance Date 2023-11-13
Abatement Due Date 2023-11-17
Current Penalty 1875.0
Initial Penalty 4688.0
Contest Date 2023-11-30
Final Order 2024-08-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(ii):The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - The employee was performing electrical work while working from a pump jack scaffold. The scaffold platform extended approximately 4 feet past the support; on or about 6/1/2023 Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2023-11-13
Abatement Due Date 2023-11-17
Current Penalty 1875.0
Initial Penalty 4688.0
Contest Date 2023-11-30
Final Order 2024-08-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - The employee was not protected from falling to the ground approximately 13.5 feet while accessing a scaffold which was more than 2 feet from the portable ladder the employee was using; on or about 06/1/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2023-11-13
Abatement Due Date 2023-11-17
Current Penalty 1875.0
Initial Penalty 4688.0
Contest Date 2023-11-30
Final Order 2024-08-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - The employee was exposed to electrical hazards while connecting energized wires from the Service Drop for 240 VAC 200 Amp service to a residential home from a scaffold less than 10 feet from the energized wires; on or about 06/1/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2023-11-13
Abatement Due Date 2023-11-17
Current Penalty 1875.0
Initial Penalty 4688.0
Contest Date 2023-11-30
Final Order 2024-08-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - The employee was not protected from falling to the ground approximately 13.5 feet while performing electrical work from a scaffold; on or about 06/1/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01007
Citaton Type Serious
Standard Cited 19260452 J02
Issuance Date 2023-11-13
Abatement Due Date 2023-11-17
Current Penalty 1875.0
Initial Penalty 4688.0
Contest Date 2023-11-30
Final Order 2024-08-16
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Worksite: 8 Nyack Drive, East Northport, NY 11731 - The scaffold pole was not secured at the bottom exposing employee to a scaffolding collapse while working approximately 13.5 feet above the ground; on or about 6/1/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Date of last update: 25 Mar 2025