150708010228 2015-07-08 CERTIFICATE OF INCORPORATION 2015-07-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341056851 0215600 2015-11-16 246-28 52ND AVE, FLUSHING, NY, 11362
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-11-16
Emphasis L: FALL, P: FALL
Case Closed 2017-06-30

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2015-11-25
Current Penalty 1000.0
Initial Penalty 2000.0
Contest Date 2016-02-17
Final Order 2016-08-26
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: On or about November 16, 2015- job site at 246-28 52nd Ave, Flushing, NY 11354 the employer permitted an employee to work on an active residential construction site, where overhead work was being performed, without a protective helmet. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B01 II
Issuance Date 2015-11-25
Current Penalty 1400.0
Initial Penalty 2800.0
Contest Date 2016-02-17
Final Order 2016-08-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): On or about November 16, 2015- job site at 246-28 52nd Ave, Flushing, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold that was not fully planked. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2015-11-25
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-02-17
Final Order 2016-08-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about November 16, 2015- job site at 246-28 52nd Ave, Flushing, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold that did not have base plates or mud sills. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2015-11-25
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-02-17
Final Order 2016-08-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access. On or about November 16, 2015- job site at 246-28 52nd Ave, Flushing, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold that did not have an access ladder and employees used the cross braces as a means of access. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2015-11-25
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-02-17
Final Order 2016-08-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: On or about November 16, 2015- job site at 246-28 52nd Ave, Flushing, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 15 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.