Search icon

PECOR CONSTRUCTION MANAGEMENT, INC.

Company Details

Name: PECOR CONSTRUCTION MANAGEMENT, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 05 Aug 2015 (10 years ago)
Entity Number: 4800392
ZIP code: 11552
County: Nassau
Place of Formation: New York
Address: 6 TERMINAL ROAD, WEST HEMPSTEAD, NY, United States, 11552

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 6 TERMINAL ROAD, WEST HEMPSTEAD, NY, United States, 11552

Filings

Filing Number Date Filed Type Effective Date
150805000716 2015-08-05 CERTIFICATE OF INCORPORATION 2015-08-05

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343618237 0214700 2018-11-26 4217 MERRICK RD., MASSAPEQUA, NY, 11758
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2018-11-26
Emphasis L: FALL
Case Closed 2019-05-09

Related Activity

Type Complaint
Activity Nr 1403180
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2018-12-13
Abatement Due Date 2018-12-19
Current Penalty 275.0
Initial Penalty 2772.0
Contest Date 2019-01-10
Final Order 2019-03-29
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Worksite - Employees were exposed to falling while working from the second tier of a fabricated frame scaffold approximately 12ft above the ground. The scaffold had four planks installed; on or about 11/26/18. b) Worksite - Employees were exposed to falling while working from the first tier of a fabricated frame scaffold approximately 6ft above the ground. The scaffold had three planks installed; on or about 11/26/18. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2018-12-13
Abatement Due Date 2018-12-19
Current Penalty 275.0
Initial Penalty 2772.0
Contest Date 2019-01-10
Final Order 2019-03-29
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Worksite - Employees were preparing for stucco application while working on a fabricated frame scaffold. The employees were climbing the crossbraces to gain access to the scaffold; on or about 11/26/18. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2018-12-13
Abatement Due Date 2018-12-19
Current Penalty 375.0
Initial Penalty 3880.0
Contest Date 2019-01-10
Final Order 2019-03-29
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a) Worksite - Employees were preparing for stucco application while working from a fabricated frame scaffold. The top of the third tier of the scaffold was approximately 6ft from the energized power lines; on or about 11/26/18. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2018-12-13
Abatement Due Date 2018-12-19
Current Penalty 275.0
Initial Penalty 2772.0
Contest Date 2019-01-10
Final Order 2019-03-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite - Employees were exposed to falling while working from the second tier of a fabricated frame scaffold, approximately 12ft above the ground; on or about 11/26/18 Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Date of last update: 25 Mar 2025