Name: | V. RIVAS CONSTRUCTION INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 13 Aug 2015 (10 years ago) |
Entity Number: | 4804127 |
ZIP code: | 11433 |
County: | Queens |
Place of Formation: | New York |
Address: | 168-21 106TH AVENUE, JQMAICA, NY, United States, 11433 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 168-21 106TH AVENUE, JQMAICA, NY, United States, 11433 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
150813000215 | 2015-08-13 | CERTIFICATE OF INCORPORATION | 2015-08-13 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342568185 | 0215600 | 2017-08-22 | 75-67 181ST STREET, FRESH MEADOWS, NY, 11366 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1257094 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19101200 E01 |
Issuance Date | 2018-02-08 |
Abatement Due Date | 2018-03-28 |
Current Penalty | 2217.0 |
Initial Penalty | 2217.0 |
Final Order | 2018-03-09 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(e)(1): Employer had not developed, implemented, and maintained a written hazard communication program included in the requirements outlined in 29 CFR 1910.1200(e)(1)(I) and (e)(1)(II): (Construction Reference: 1926.59) (a) On or about August 22 2017, at 75-67 181st Street, Fresh Meadows NY 11366 The employer had not developed a written hazard communication program for employees using hazardous chemicals including, but not limited to Essroc i.pro Type N Cement containing portland cement, while laying bricks on the exterior of a two story renovation project of a residential home. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19101200 G08 |
Issuance Date | 2018-02-08 |
Abatement Due Date | 2018-03-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-09 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in workplace: (Construction Reference: 1926.59) (a) On or about August 22 2017, at 75-67 181st Street, Fresh Meadows NY 11366 The employer did not maintain and provide to employees, copies of the required safety data sheets for each hazardous chemical including but not limited to Essroc i.pro Type N Cement containing portland cement, while laying bricks on the exterior of a two story renovation project of a residential home. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19101200 H01 |
Issuance Date | 2018-02-08 |
Abatement Due Date | 2018-03-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-09 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(h)(1): The Employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area: (Construction Reference: 1926.59) (a) On or about August 22 2017, at 75-67 181st Street, Fresh Meadows NY 11366 The employer did not provide hazardous communication information and training to employees who used hazardous chemicals including but not limited to Essroc i.pro Type N Cement containing portland cement, while laying bricks on the exterior of a two story renovation project of a residential home. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100134 K06 |
Issuance Date | 2018-02-08 |
Abatement Due Date | 2018-03-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-09 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(k)(6): The employer did not provide basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134 in written or oral format, to employees who wear respirators when such use is not required by this section or by the employer. (Construction Reference: 1926.103) (a) On or about August 22 2017, at 75-67 181st Street, Fresh Meadows NY 11366 The employer did not provide information on Appendix D of 29 CFR 1910.134 to employees who voluntarily used N95 dust masks for protection from silica dust while using hazardous chemicals including but not limited to Essroc i.pro Type N Cement and sand containing silica, while laying bricks on the exterior of a two story renovation project of a residential home. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2017-08-22 |
Emphasis | L: FALL, P: FALL |
Related Activity
Type | Inspection |
Activity Nr | 1256818 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2018-02-08 |
Current Penalty | 1663.0 |
Initial Penalty | 1663.0 |
Final Order | 2018-03-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A.) On or about August 22, 2017 at 75-67 181st Street, Fresh Meadows, NY 11366 Employees working directly below a material hoisting operation were observed working without hard hats exposed to struck-by hazards. ABATEMENT CERTIFICATION IS NOT REQUIRED |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2018-02-08 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: A.) On or about August 22, 2017 at 75-67 181st Street, Fresh Meadows, NY 11366 Employees observed hoisting construction material along the unprotected side/edge of a tubular welded scaffold approximately eighteen (18) feet above the lower level. ABATEMENT CERTIFICATION IS NOT REQUIRED |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2018-02-08 |
Current Penalty | 2772.0 |
Initial Penalty | 2772.0 |
Final Order | 2018-03-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: 1.) On or about August 22, 2017 at 75-67 181st Street, Fresh Meadows, NY 11366 A portable ladder used by employees to access a tubular welded scaffold work platform erected approximately eighteen (18) feet above the lower level was not extended at least three (3) feet above the upper landing surface exposing employees to fall hazards. ABATEMENT CERTIFICATION IS NOT REQUIRED |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260451 C02 |
Issuance Date | 2018-02-08 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-09 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: A.) On or about August 22, 2017 at 75-67 181st Street, Fresh Meadows, NY 11366 A tubular welded scaffold erected approximately eighteen (18) feet above the lower level used was observed missing adequate firm foundation such as base plates and mud sills exposing employees to fall hazards. ABATEMENT CERTIFICATION IS NOT REQUIRED |