Search icon

BUFFALO NIAGARA GUN RANGE, INC.

Company Details

Name: BUFFALO NIAGARA GUN RANGE, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 26 Aug 2015 (10 years ago)
Entity Number: 4810593
ZIP code: 14051
County: Erie
Place of Formation: New York
Address: 8 KRISTEN MEADOWS, EAST AMHERST, NY, United States, 14051

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Commercial and government entity program

CAGE number Status Type Established CAGE Update Date CAGE Expiration SAM Expiration
34YL5 Obsolete Non-Manufacturer 2005-01-12 2024-05-07 2024-05-06 No data

Contact Information

POC PAUL VALERA
Phone +1 716-693-4000
Fax +1 716-693-4044
Address 3355 NIAGARA FALLS BLVD, NORTH TONAWANDA, NIAGARA, NY, 14120 1213, UNITED STATES

Ownership of Offeror Information

Highest Level Owner Information not Available
Immediate Level Owner Information not Available
List of Offerors (0) Information not Available

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 8 KRISTEN MEADOWS, EAST AMHERST, NY, United States, 14051

History

Start date End date Type Value
2015-08-26 2021-08-24 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
150826010025 2015-08-26 CERTIFICATE OF INCORPORATION 2015-08-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343922027 0213600 2019-04-11 3355 NIAGARA FALLS BOULEVARD, NORTH TONAWANDA, NY, 14120
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2019-06-13
Emphasis N: LEAD
Case Closed 2019-12-09

Related Activity

Type Referral
Activity Nr 1444632
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100095 C01
Issuance Date 2019-08-28
Abatement Due Date 2019-09-30
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a) 50-yard indoor gun firing range - On or about 04/18/2019, range employees assisting rental customers were exposed to continuous noise at approximately 124.6% of the permissible daily noise level (8-hour time-weighted average sound level of 90 dBA) or an equivalent sound level of approximately 91.58 dBA during the 129 minute sampling period on April 18, 2019; exposure calculations included a zero increment for the 351 minutes not sampled. The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100095 G01
Issuance Date 2019-08-28
Abatement Due Date 2019-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: a) 50-yard indoor gun firing range - On or about 04/18/2019, range employees assisting rental customers were exposed to continuous noise at approximately 124.6% of the permissible daily noise level (8-hour time-weighted average sound level of 90 dBA) or an equivalent sound level of approximately 91.58 dBA during the 129 minute sampling period on April 18, 2019; exposure calculations included a zero increment for the 351 minutes not sampled. The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100095 K01
Issuance Date 2019-08-28
Abatement Due Date 2019-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k). The employer did not institute a training program and ensure employee participation in the program: a) 50-yard indoor gun firing range - On or about 04/18/2019, range employees assisting rental customers were exposed to continuous noise at approximately 124.6% of the permissible daily noise level (8-hour time-weighted average sound level of 90 dBA) or an equivalent sound level of approximately 91.58 dBA during the 129 minute sampling period on April 18, 2019; exposure calculations included a zero increment for the 351 minutes not sampled. The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k). The employer did not institute a training program and ensure employee participation in the program. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2019-08-28
Abatement Due Date 2019-09-30
Current Penalty 2273.0
Initial Penalty 2273.0
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) 50-yard indoor gun firing range - On or about 04/18/2019, range employees cleaning the range at the completion of the day required to don a half-face, negative pressure, air purifying respirator (NORTH) when a written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use. b) 50-yard indoor gun firing range - On or about 04/18/2019, range employees assisting rental customers required to don a filtering facepiece, negative pressure, air purifying respirator (3M) when a written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2019-08-28
Abatement Due Date 2019-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-09-25
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Note: The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.) a) 50-yard indoor gun firing range - On or about 04/18/2019, the employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before range employees were required to don a half-face, negative pressure, air purifying respirator (NORTH) when cleaning the range. b) 50-yard indoor gun firing range - On or about 04/18/2019, the employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before range employees were required to use a filtering face piece (3M) when assisting rental customers on the range. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2019-08-28
Abatement Due Date 2019-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) 50-yard indoor gun firing range - On or about 04/18/2019, the employer did not ensure that range employee(s) required to don a half-face, negative pressure, air purifying respirator (NORTH) to clean the range at the completion of the day, passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) . b) 50-yard indoor gun firing range - On or about 04/18/2019, the employer did not ensure that range employee(s) required to don a filtering facepiece, negative pressure, air purifying respirator (3M) to clean the range at the completion of the day, passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) . ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002D
Citaton Type Serious
Standard Cited 19100134 K
Issuance Date 2019-08-28
Abatement Due Date 2019-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-09-25
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k): The employer did not provide comprehensive, understandable, and effective annual training to employees who were required to use respirators. a) 50-yard indoor gun firing range - On or about 04/18/2019, the employer did not provide comprehensive, understandable, and effective annual training to range employees who were required to use half-face, negative pressure, air purifying respirator (NORTH) to clean the range. b) 50-yard indoor gun firing range - On or about 04/18/2019, the employer did not provide comprehensive, understandable, and effective annual training to range employees who were required to use filtering facepiece respirators (3M) when assisting rental customers on the range. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003A
Citaton Type Serious
Standard Cited 19101025 D02
Issuance Date 2019-08-28
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-09-25
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level: a) 50-yard indoor gun firing range - On or about 04/18/2019, the employer did not make an initial determination to determine if range employees assisting rental customers on the range may be exposed to lead at or above the action level from using lead bullets and/or lead-containing primers. b) 50-yard indoor gun firing range - On or about 04/18/2019, the employer did not make an initial determination to determine if range employees performing clean-up operations may be exposed to lead at or above the action level from residue left from use of lead bullets and/or lead-containing primers. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003B
Citaton Type Serious
Standard Cited 19101025 L01 I
Issuance Date 2019-08-28
Abatement Due Date 2019-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025: a) 50-yard indoor gun firing range - On or about 04/18/2019, range employees assisting rental customers where there was potential exposure to airborne levels of lead from using lead bullets and/or lead-containing primers were not informed of the content of Appendices A and B of 29 CFR 1910.1025. b) 50-yard indoor gun firing range - On or about 04/18/2019, range employees performing clean-up operations where there was potential exposure to airborne levels of lead from using lead bullets and/or lead-containing primers were not informed of the content of Appendices A and B of 29 CFR 1910.1025. ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2019-08-28
Abatement Due Date 2019-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) 50-yard indoor gun firing range - On or about 04/18/2019, the employer did not develop, implement, and/or maintain at the workplace a written hazard communication program. Employees working in the range use chemicals such as but not limited to which contains D-Lead Soap, an eye irritant containing sodium chloride. A written program should include descriptions of how the criteria for: 1. Labeling and other forms of warning; 2. Material Safety Data Sheets AND 3. Employee information and training will be met. Additionally, a list of hazardous chemicals known to be present in the workplace must be compiled. Methods used to inform employees of the hazards associated with non-routine tasks and the informing of contractors of workplace hazard must also be addressed. The written program must be made available upon request. ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001B
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2019-08-28
Abatement Due Date 2019-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-09-25
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) 50-yard indoor gun firing range - On or about 04/18/2019, employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area. Employees working in the range use chemicals such as but not limited to which contains D-Lead Soap, an eye irritant containing sodium chloride. Employees shall be informed of: 1. The requirements of this section: 2. Any operations where hazardous chemicals are present; AND 3. The location and availability of the written Hazard Communication Program, list(s) of hazardous chemicals and Material Safety Data Sheets. Employee training shall include at least: 1. Methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area. 2. The physical and health hazards of the chemicals in the work area. 3. The measures employees can take to protect themselves such as specific procedures, appropriate work practices, emergency procedures and personal protective equipment to be used. 4. The details of the employers Hazard Communication Program including an explanation of labeling systems, Material Safety Data Sheets and how employees can obtain and use the appropriate hazard information. ABATEMENT CERTIFICATION REQUIRED

Date of last update: 25 Mar 2025