Name: | FLEXO TRANSPARENT, LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 15 Sep 2015 (9 years ago) |
Entity Number: | 4819997 |
ZIP code: | 12207 |
County: | Erie |
Place of Formation: | New York |
Address: | 80 STATE STREET, ALBANY, NY, United States, 12207 |
Plan Name | Plan Year | EIN/PN | Received | Sponsor | Total number of participants | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FLEXO TRANSPARENT 401(K) PLAN | 2020 | 475100551 | 2022-10-14 | FLEXO TRANSPARENT, LLC | 37 | |||||||||||||||||||||||||||||
|
Role | Plan administrator |
Date | 2022-10-14 |
Name of individual signing | BRET BOWERSOX |
Role | Employer/plan sponsor |
Date | 2022-10-14 |
Name of individual signing | BRET BOWERSOX |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 1997-01-01 |
Business code | 323100 |
Sponsor’s telephone number | 7168257710 |
Plan sponsor’s address | 28 WASSON STREET, BUFFALO, NY, 14210 |
Signature of
Role | Plan administrator |
Date | 2020-10-06 |
Name of individual signing | BRET BOWERSOX |
Role | Employer/plan sponsor |
Date | 2020-10-06 |
Name of individual signing | BRET BOWERSOX |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 1997-01-01 |
Business code | 323100 |
Sponsor’s telephone number | 7168257710 |
Plan sponsor’s address | 28 WASSON STREET, BUFFALO, NY, 14210 |
Signature of
Role | Plan administrator |
Date | 2019-06-17 |
Name of individual signing | BRIAN MABRY |
Role | Employer/plan sponsor |
Date | 2019-06-17 |
Name of individual signing | BRIAN MABRY |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 1997-01-01 |
Business code | 323100 |
Sponsor’s telephone number | 7168257710 |
Plan sponsor’s address | 28 WASSON STREET, BUFFALO, NY, 14210 |
Signature of
Role | Plan administrator |
Date | 2018-09-07 |
Name of individual signing | BRIAN MABRY |
Role | Employer/plan sponsor |
Date | 2018-09-07 |
Name of individual signing | BRIAN MABRY |
File | View Page |
Three-digit plan number (PN) | 001 |
Effective date of plan | 1997-01-01 |
Business code | 323100 |
Sponsor’s telephone number | 7168257710 |
Plan sponsor’s address | 28 WASSON STREET, BUFFALO, NY, 14210 |
Signature of
Role | Plan administrator |
Date | 2017-08-31 |
Name of individual signing | BRIAN MABRY |
Role | Employer/plan sponsor |
Date | 2017-08-31 |
Name of individual signing | BRIAN MABRY |
Name | Role | Address |
---|---|---|
CORPORATION SERVICE COMPANY | DOS Process Agent | 80 STATE STREET, ALBANY, NY, United States, 12207 |
Start date | End date | Type | Value |
---|---|---|---|
2019-03-08 | 2024-06-28 | Address | 28 WASSON STREET, BUFFALO, NY, 14210, 0128, USA (Type of address: Service of Process) |
2015-09-29 | 2019-03-08 | Address | 28 WASSON STREET, BUFFALO, NY, 14210, 0128, USA (Type of address: Service of Process) |
2015-09-23 | 2015-09-29 | Address | 28 WASSON STREET, BUFFALO, NY, 14210, USA (Type of address: Service of Process) |
2015-09-15 | 2015-09-23 | Address | 28 WASSON STREET, BUFFALO, NY, 14210, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
240628000789 | 2024-06-28 | BIENNIAL STATEMENT | 2024-06-28 |
221028003150 | 2022-10-28 | BIENNIAL STATEMENT | 2021-09-01 |
200520060036 | 2020-05-20 | BIENNIAL STATEMENT | 2019-09-01 |
190308000379 | 2019-03-08 | CERTIFICATE OF MERGER | 2019-03-08 |
190114061024 | 2019-01-14 | BIENNIAL STATEMENT | 2017-09-01 |
150929000312 | 2015-09-29 | CERTIFICATE OF MERGER | 2015-09-29 |
150923000656 | 2015-09-23 | CERTIFICATE OF MERGER | 2015-09-23 |
150915000654 | 2015-09-15 | ARTICLES OF ORGANIZATION | 2015-09-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342759289 | 0213600 | 2017-11-07 | 28 WASSON ST., BUFFALO, NY, 14240 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100028 B01 I |
Issuance Date | 2018-01-18 |
Abatement Due Date | 2018-02-20 |
Current Penalty | 5000.0 |
Initial Penalty | 8315.0 |
Final Order | 2018-02-12 |
Nr Instances | 5 |
Nr Exposed | 24 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) On or about 01/11/18 in the Printing department; employees made adjustments to the anilox, changed/cleaned the doctor blades and seals, on the pressman and assistant side of Press 6-1 and were exposed to an unprotected fall of 54 inches while they stood on a work surface 3.5 inches wide by 55 inches in length. b) On or about 01/11/18 in the Press department; employees made adjustments to the anilox, changed/cleaned the doctor blades and seals on the pressman and assistant side of Press 6-2 and were exposed to an unprotected fall of 57 inches while they stood on a work surface 3.5 inches wide by 55 inches in length. c) On or about 01/11/18 in the Press department; employees made adjustments to the anilox, changed/cleaned the doctor blades and seals on the pressman and assistant side of Press M-8 and were exposed to an unprotected fall of 51 & 84 inches while they stood on a work surface 3.5 inches wide by 60 inches in length. d) On or about 01/11/18 in the Press department; employees made adjustments to the anilox, changed/cleaned the doctor blades and seals on the pressman and assistant side of Press F&F and were exposed to an unprotected fall of 84 inches while they stood on a work surface approximately 20 inches wide by 60 inches in length. e) On or about 01/11/18 in the Press department; employees made adjustments to the anilox, changed/cleaned the doctor blade and seals on the north side of newly installed Bobst press and were exposed to an unprotected fall of approximately 84 inches while they stood on a work surface approximately 24 inches wide by 60 inches in length. ABATEMENT DOCUMENTATION REQUIRED |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19100147 C07 I A |
Issuance Date | 2018-01-18 |
Current Penalty | 3000.0 |
Initial Penalty | 4989.0 |
Final Order | 2018-02-12 |
Nr Instances | 2 |
Nr Exposed | 6 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the methods and means necessary for energy isolation: a) On or about 11/07/17 in the Converting Department; employees who serviced and maintained the Roan machines, such as but not limited to, cleaning the Bronco drive rollers, drum, slicer roller, were exposed to a caught between hazard when they were not trained to attach energy control devices to the energy isolation devices. b) On or about 11/07/17 in the Converting Department; employees who serviced and maintained the M85-1 machines, such as but not limited to, adjusting the punches, aligning the film feed, were exposed to caught between hazards when they were not trained to attach energy control devices to the energy isolation devices. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19100147 D04 I |
Issuance Date | 2018-01-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-02-12 |
Nr Instances | 2 |
Nr Exposed | 6 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) On or about 11/07/17 in the Converting Department; employees who serviced and maintained the Roan machines, such as but not limited to, cleaning the Bronco drive rollers, drum, slicer roller, were exposed to a caught between hazard when they did not attach energy control devices to the energy isolation devices. b) On or about 11/07/17 in the Converting Department; employees who serviced and maintained the M85-1 machines, such as but not limited to, adjusting the punches, aligning the film feed, were exposed to a caught between hazard when they did not attach energy control devices to the energy isolation devices. NO ABATEMENT CERTIFICATION REQUIRED |
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1816576 | Intrastate Non-Hazmat | 2022-08-05 | 15435 | 2016 | 2 | 15 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Date of last update: 18 Feb 2025
Sources: New York Secretary of State