Search icon

MC DELTA ROOFING LLC

Company Details

Name: MC DELTA ROOFING LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Inactive
Date of registration: 17 Sep 2015 (10 years ago)
Date of dissolution: 22 Jun 2020
Entity Number: 4821614
ZIP code: 11201
County: Kings
Place of Formation: New York
Address: 44 COURT STREET SUIT 1217, BROOKLYN, NY, United States, 11201

Contact Details

Phone +1 718-928-8071

DOS Process Agent

Name Role Address
BLENZY COSTELLO DOS Process Agent 44 COURT STREET SUIT 1217, BROOKLYN, NY, United States, 11201

Licenses

Number Status Type Date End date
2070167-DCA Inactive Business 2018-04-27 2021-02-28
2028952-DCA Inactive Business 2015-09-30 2017-02-28

Filings

Filing Number Date Filed Type Effective Date
200622000279 2020-06-22 ARTICLES OF DISSOLUTION 2020-06-22
150917010434 2015-09-17 ARTICLES OF ORGANIZATION 2015-09-17

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
2976859 RENEWAL INVOICED 2019-02-06 100 Home Improvement Contractor License Renewal Fee
2976858 TRUSTFUNDHIC INVOICED 2019-02-06 200 Home Improvement Contractor Trust Fund Enrollment Fee
2772679 TRUSTFUNDHIC INVOICED 2018-04-09 200 Home Improvement Contractor Trust Fund Enrollment Fee
2772678 LICENSE INVOICED 2018-04-09 50 Home Improvement Contractor License Fee
2174359 LICENSE INVOICED 2015-09-21 75 Home Improvement Contractor License Fee
2174360 TRUSTFUNDHIC INVOICED 2015-09-21 200 Home Improvement Contractor Trust Fund Enrollment Fee
2174389 FINGERPRINT INVOICED 2015-09-21 75 Fingerprint Fee
2174363 FINGERPRINT INVOICED 2015-09-21 75 Fingerprint Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343149365 0216000 2018-05-02 77 LAFAYETTE AVENUE, N WHITE PLAINS, NY, 10603
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2018-06-19
Emphasis L: FALL
Case Closed 2023-02-06

Related Activity

Type Complaint
Activity Nr 1336513
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2018-06-28
Current Penalty 1400.0
Initial Penalty 2217.0
Final Order 2018-07-26
Nr Instances 6
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: Location: entire site On or about: 5/2/18 a) Employees, who were working below overhead hazards related to roofing work, were not provided with hard hats. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260852 A
Issuance Date 2018-06-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-07-26
Nr Instances 6
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.852(a): Material was dropped to points lying outside the exterior walls of the structure which had not been effectively protected: Location: dumpster area On or about: 5/2/18 a) Employees were throwing roofing materials off the roof to a dumpster below. The area below was not effectively protected. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2018-06-28
Current Penalty 3600.0
Initial Penalty 5174.0
Final Order 2018-07-26
Nr Instances 2
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted: location: upper and lower roof on or about: 5/2/18 a) Employees, engaged in roofing activities, were not using any means of fall protection. The employees were exposed to a fall of up to 20 feet.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2018-06-28
Current Penalty 0.0
Initial Penalty 3696.0
Final Order 2018-07-26
Nr Instances 5
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: location: entire site on or about: 5/2/18 a) Employee, exposed to a fall hazard while engaged in roofing activities, were not provided with fall protection training. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 02001A
Citaton Type Other
Standard Cited 19261053 B01
Issuance Date 2018-06-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-07-26
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder: location: ladder between ground and lower roof on or about: 5/2/18 a) Employees were using an metal extension ladder to access the lower roof. The ladder extended above the roof surface 2 1/2 feet.
Citation ID 02001B
Citaton Type Other
Standard Cited 19261060 A
Issuance Date 2018-06-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-07-26
Nr Instances 5
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary: location: entire site on or about: 5/2/18 a) Employees were using metal extension ladders to access the roof. The employees were not provided with ladder safety training. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.