Search icon

ALDO'S MASONRY INC

Company Details

Name: ALDO'S MASONRY INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 23 Sep 2015 (10 years ago)
Entity Number: 4824170
ZIP code: 10308
County: Richmond
Place of Formation: New York
Address: 94 Escanaba Avenue, Staten Island, NY, United States, 10308

Contact Details

Phone +1 718-980-1018

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
ALDO'S MASONRY INC DOS Process Agent 94 Escanaba Avenue, Staten Island, NY, United States, 10308

Chief Executive Officer

Name Role Address
ALMEDIN MERSIMOVSKI Chief Executive Officer 94 ESCANABA AVENUE, STATEN ISLAND, NY, United States, 10308

Licenses

Number Status Type Date End date
2031144-DCA Active Business 2015-12-08 2025-02-28

History

Start date End date Type Value
2015-09-23 2023-04-07 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2015-09-23 2023-04-07 Address 94 ESCANABA AVE, STATEN ISLAND, NY, 10308, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
230407000468 2023-04-07 BIENNIAL STATEMENT 2021-09-01
150923010190 2015-09-23 CERTIFICATE OF INCORPORATION 2015-09-23

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
3549247 TRUSTFUNDHIC INVOICED 2022-11-03 200 Home Improvement Contractor Trust Fund Enrollment Fee
3549248 RENEWAL INVOICED 2022-11-03 100 Home Improvement Contractor License Renewal Fee
3259661 TRUSTFUNDHIC INVOICED 2020-11-19 200 Home Improvement Contractor Trust Fund Enrollment Fee
3259662 RENEWAL INVOICED 2020-11-19 100 Home Improvement Contractor License Renewal Fee
2969359 TRUSTFUNDHIC INVOICED 2019-01-28 200 Home Improvement Contractor Trust Fund Enrollment Fee
2969360 RENEWAL INVOICED 2019-01-28 100 Home Improvement Contractor License Renewal Fee
2478358 TRUSTFUNDHIC INVOICED 2016-10-29 200 Home Improvement Contractor Trust Fund Enrollment Fee
2478359 RENEWAL INVOICED 2016-10-29 100 Home Improvement Contractor License Renewal Fee
2271663 LICENSEDOC10 INVOICED 2016-02-03 10 License Document Replacement
2226391 TRUSTFUNDHIC INVOICED 2015-12-02 200 Home Improvement Contractor Trust Fund Enrollment Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346918840 0215000 2023-08-18 7621 12TH AVENUE, BROOKLYN, NY, 11228
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-08-18
Emphasis N: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2024-01-23
Current Penalty 4839.0
Initial Penalty 4839.0
Contest Date 2024-02-20
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1):Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports. Location: Worksite; front facing fa�ade of residence. a) On or about 08/18/2023, employees worked on a 2-tier tubular welded frame scaffold that was not fully planked or decked between the front uprights and the guardrail supports.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2024-01-23
Current Penalty 4839.0
Initial Penalty 4839.0
Contest Date 2024-02-20
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces shall not be used as a means of access. Location: Worksite; front facing fa�ade of residence. a) On or about 08/18/2023, employees working from a 2-tier high tubular welded frame scaffold that did not have a safe means of access. Employees climbed the frames and cross braces to access the working platforms.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2024-01-23
Current Penalty 4839.0
Initial Penalty 4839.0
Contest Date 2024-02-20
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: Worksite; front facing fa�ade of residence. a) On or about 08/18/2023, employees worked on a 2-tier high tubular welded frame scaffold and the scaffold was not equipped for guardrails.

Date of last update: 25 Mar 2025

Sources: New York Secretary of State