Name: | 125 MAIN STREET REALTY CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 21 Oct 2015 (9 years ago) |
Entity Number: | 4837637 |
ZIP code: | 10562 |
County: | Westchester |
Place of Formation: | New York |
Address: | 11 LAKEVIEW ROAD, OSSINING, NY, United States, 10562 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
PEDRO SILVA | Chief Executive Officer | 125 MAIN STREET, OSSINING, NY, United States, 19562 |
Name | Role | Address |
---|---|---|
PEDRO SILVA | DOS Process Agent | 11 LAKEVIEW ROAD, OSSINING, NY, United States, 10562 |
Start date | End date | Type | Value |
---|---|---|---|
2015-10-21 | 2019-10-25 | Address | 125 MAIN STREET, OSSINING, NY, 10562, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
191025060205 | 2019-10-25 | BIENNIAL STATEMENT | 2019-10-01 |
151021010247 | 2015-10-21 | CERTIFICATE OF INCORPORATION | 2015-10-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347497497 | 0216000 | 2024-06-12 | 12 WHITER ST. SUITE C, BUCHANAN, NY, 10511 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 2165405 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100213 C01 |
Issuance Date | 2024-07-24 |
Abatement Due Date | 2024-08-12 |
Current Penalty | 4839.0 |
Initial Penalty | 4839.0 |
Final Order | 2024-08-26 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.213(c)(1):Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: location: Suite D on or about: 5/13/24 a) An employee was operating a Delta table saw to rip wood while manufacturing furniture. The blade of the saw was not guarded. Note: In addition to abatement certification, the employer is required to provide abatement documentation for this item in accordance with 29 CFR 1903.19 |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100213 C02 |
Issuance Date | 2024-07-24 |
Abatement Due Date | 2024-08-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-08-26 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: location: Suite D on or about: 5/13/24 a) An employee was operating a Delta table saw to rip wood while manufacturing furniture. The saw was not furnished with a spreader. Note: In addition to abatement certification, the employer is required to provide abatement documentation for this item in accordance with 29 CFR 1903.19 |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19100213 C03 |
Issuance Date | 2024-07-24 |
Abatement Due Date | 2024-08-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-08-26 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: location: Suite D on or about: 5/13/24 a) An employee was operating a Delta table saw to rip wood while manufacturing furniture. The saw did not have non kickback fingers or dogs. Note: In addition to abatement certification, the employer is required to provide abatement documentation for this item in accordance with 29 CFR 1903.19 |
Citation ID | 01001D |
Citaton Type | Serious |
Standard Cited | 19100213 D01 |
Issuance Date | 2024-07-24 |
Abatement Due Date | 2024-08-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-08-26 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: location: Suite D on or about: 5/13/24 a) An employee was operating a Delta table saw to rip wood while manufacturing furniture. The blade of the saw was not guarded. Note: In addition to abatement certification, the employer is required to provide abatement documentation for this item in accordance with 29 CFR 1903.19 |