Search icon

125 MAIN STREET REALTY CORP.

Company Details

Name: 125 MAIN STREET REALTY CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 21 Oct 2015 (9 years ago)
Entity Number: 4837637
ZIP code: 10562
County: Westchester
Place of Formation: New York
Address: 11 LAKEVIEW ROAD, OSSINING, NY, United States, 10562

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
PEDRO SILVA Chief Executive Officer 125 MAIN STREET, OSSINING, NY, United States, 19562

DOS Process Agent

Name Role Address
PEDRO SILVA DOS Process Agent 11 LAKEVIEW ROAD, OSSINING, NY, United States, 10562

History

Start date End date Type Value
2015-10-21 2019-10-25 Address 125 MAIN STREET, OSSINING, NY, 10562, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
191025060205 2019-10-25 BIENNIAL STATEMENT 2019-10-01
151021010247 2015-10-21 CERTIFICATE OF INCORPORATION 2015-10-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347497497 0216000 2024-06-12 12 WHITER ST. SUITE C, BUCHANAN, NY, 10511
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-07-16
Emphasis N: AMPUTATE
Case Closed 2025-01-23

Related Activity

Type Referral
Activity Nr 2165405
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100213 C01
Issuance Date 2024-07-24
Abatement Due Date 2024-08-12
Current Penalty 4839.0
Initial Penalty 4839.0
Final Order 2024-08-26
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(1):Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: location: Suite D on or about: 5/13/24 a) An employee was operating a Delta table saw to rip wood while manufacturing furniture. The blade of the saw was not guarded. Note: In addition to abatement certification, the employer is required to provide abatement documentation for this item in accordance with 29 CFR 1903.19
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100213 C02
Issuance Date 2024-07-24
Abatement Due Date 2024-08-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-26
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: location: Suite D on or about: 5/13/24 a) An employee was operating a Delta table saw to rip wood while manufacturing furniture. The saw was not furnished with a spreader. Note: In addition to abatement certification, the employer is required to provide abatement documentation for this item in accordance with 29 CFR 1903.19
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100213 C03
Issuance Date 2024-07-24
Abatement Due Date 2024-08-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-26
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: location: Suite D on or about: 5/13/24 a) An employee was operating a Delta table saw to rip wood while manufacturing furniture. The saw did not have non kickback fingers or dogs. Note: In addition to abatement certification, the employer is required to provide abatement documentation for this item in accordance with 29 CFR 1903.19
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100213 D01
Issuance Date 2024-07-24
Abatement Due Date 2024-08-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-26
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: location: Suite D on or about: 5/13/24 a) An employee was operating a Delta table saw to rip wood while manufacturing furniture. The blade of the saw was not guarded. Note: In addition to abatement certification, the employer is required to provide abatement documentation for this item in accordance with 29 CFR 1903.19