Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2022-08-23
|
Emphasis |
L: FALL, P: LOCALTARG, L: LOCALTARG
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B06 |
Issuance Date |
2023-01-25 |
Abatement Due Date |
2023-01-31 |
Current Penalty |
7813.0 |
Initial Penalty |
7813.0 |
Contest Date |
2023-02-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(6): Each employee on ramps, runways, and other walkways was not protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems: a) Worksite - On or about August 23, 2022, an employee was exposed to fall hazards of approximately 10.75 feet when walking on a ramp leading into the building without a guardrail system in place. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B14 |
Issuance Date |
2023-01-25 |
Abatement Due Date |
2023-01-31 |
Current Penalty |
7813.0 |
Initial Penalty |
7813.0 |
Contest Date |
2023-02-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. a) Worksite - On or about August 23, 2022, an employee was exposed to fall hazards of approximately 16 feet while working above the approximately 8 feet wide window wall opening. The distance from the floor to the bottom edge of the window wall opening was approximately 34 inches. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040029 A |
Issuance Date |
2023-01-25 |
Abatement Due Date |
2023-01-31 |
Current Penalty |
1562.0 |
Initial Penalty |
1562.0 |
Contest Date |
2023-02-16 |
Nr Instances |
1 |
Nr Exposed |
26 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.29(a):The employer did not use an OSHA 300, 301 and 300A Form or equivalent. a) On or prior to August 23, 2022, the employer did not keep OSHA 300 and 300a logs for years 2019, 2020, 2021, and 2022. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260405 A02 II E |
Issuance Date |
2023-01-25 |
Abatement Due Date |
2023-01-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2023-02-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(E):Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a) Worksite - On or about August 23, 2022, light bulbs throughout the worksite were missing protective caps. |
|
|