Search icon

CAPTAIN BUILDERS INC

Company Details

Name: CAPTAIN BUILDERS INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 06 Nov 2015 (9 years ago)
Date of dissolution: 24 Dec 2020
Entity Number: 4846579
ZIP code: 11234
County: Kings
Place of Formation: New York
Address: 5802 AVENUE N, BROOKLYN, NY, United States, 11234

Contact Details

Phone +1 718-314-3671

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 5802 AVENUE N, BROOKLYN, NY, United States, 11234

Licenses

Number Status Type Date End date
2031077-DCA Inactive Business 2015-12-04 2021-02-28

Permits

Number Date End date Type Address
B012019331C95 2019-11-27 2019-12-25 RESET, REPAIR OR REPLACE CURB 65 STREET, BROOKLYN, FROM STREET 13 AVENUE TO STREET 14 AVENUE
B012019086A19 2019-03-27 2019-04-24 RESET, REPAIR OR REPLACE CURB 21 AVENUE, BROOKLYN, FROM STREET 84 STREET TO STREET 85 STREET
B012018344C90 2018-12-10 2018-12-31 RESET, REPAIR OR REPLACE CURB 65 STREET, BROOKLYN, FROM STREET 10 AVENUE TO STREET 11 AVENUE

Filings

Filing Number Date Filed Type Effective Date
201224000340 2020-12-24 CERTIFICATE OF DISSOLUTION 2020-12-24
151106010355 2015-11-06 CERTIFICATE OF INCORPORATION 2015-11-06

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2022-08-03 No data 65 STREET, FROM STREET 13 AVENUE TO STREET 14 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb installed in compliance
2022-03-14 No data 21 AVENUE, FROM STREET 84 STREET TO STREET 85 STREET No data Street Construction Inspections: Post-Audit Department of Transportation curb acceptable
2021-09-12 No data MC DONALD AVENUE, FROM STREET 65 STREET TO STREET AVENUE O No data Street Construction Inspections: Post-Audit Department of Transportation s/w installed
2021-08-07 No data 65 STREET, FROM STREET 10 AVENUE TO STREET 11 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb installed near 11th Ave aka 6502 11th Ave
2021-07-06 No data EAST 21 STREET, FROM STREET AVENUE X TO STREET AVENUE Y No data Street Construction Inspections: Post-Audit Department of Transportation curb installation acceptable
2021-06-15 No data 21 AVENUE, FROM STREET 84 STREET TO STREET 85 STREET No data Street Construction Inspections: Post-Audit Department of Transportation Curb installed.
2021-05-28 No data 65 STREET, FROM STREET 13 AVENUE TO STREET 14 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation New curb installed.
2021-05-22 No data NARROWS AVENUE, FROM STREET 73 STREET TO STREET 74 STREET No data Street Construction Inspections: Post-Audit Department of Transportation Sidewalk Repair in Compliance
2021-03-31 No data LAMBERTS LANE, FROM STREET CROTON PLACE TO STREET RICHMOND AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation SIDEWALK FLAGS ARE OK
2021-01-09 No data 6 AVENUE, FROM STREET 57 STREET TO STREET 58 STREET No data Street Construction Inspections: Post-Audit Department of Transportation Sidewalk is in compliance.

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
2965884 RENEWAL INVOICED 2019-01-22 100 Home Improvement Contractor License Renewal Fee
2965883 TRUSTFUNDHIC INVOICED 2019-01-22 200 Home Improvement Contractor Trust Fund Enrollment Fee
2511405 TRUSTFUNDHIC INVOICED 2016-12-13 200 Home Improvement Contractor Trust Fund Enrollment Fee
2511446 RENEWAL INVOICED 2016-12-13 100 Home Improvement Contractor License Renewal Fee
2224083 LICENSE INVOICED 2015-11-27 75 Home Improvement Contractor License Fee
2224084 TRUSTFUNDHIC INVOICED 2015-11-27 200 Home Improvement Contractor Trust Fund Enrollment Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342385549 0215000 2017-06-08 39 MONROE ST., NEW YORK, NY, 10002
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2017-06-08
Emphasis P: LOCALTARG, L: LOCALTARG
Case Closed 2021-05-14

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260025 A
Issuance Date 2017-11-16
Current Penalty 3803.0
Initial Penalty 3803.0
Final Order 2018-02-27
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures. a) First floor, near jobsite entrance: Construction debris was stored in work areas and passageways that obstructed access and egress from the jobsite entrance. On or about 06/08/17.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2017-11-16
Current Penalty 3803.0
Initial Penalty 3803.0
Final Order 2018-02-27
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) 3rd floor kitchen area: An employee used an electric powered angle grinder to do framing work. The angle grinder was designed to accommodate a guard for the cutting wheel, and was not equipped with such guard when in use. On or about 06/08/17.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2017-11-16
Current Penalty 3803.0
Initial Penalty 3803.0
Final Order 2018-02-27
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) 3rd floor kitchen area: Employees used a chop saw and an angle grinder to do carpentry work. The tools were connected to an extension cord, which was routed to a nearby outlet device and was not provided with a ground fault circuit interrupter. On or about 06/08/17.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2017-11-16
Current Penalty 3803.0
Initial Penalty 3803.0
Final Order 2018-02-27
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. a) 3rd floor kitchen area: Employees used a chop saw and an angle grinder to do carpentry work. The tools were connected to an extension cord, which was routed to a nearby outlet device. The extension cord was missing a ground pin. On or about 06/08/17.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2017-11-16
Current Penalty 3803.0
Initial Penalty 3803.0
Final Order 2018-02-27
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) 6-story high supported scaffold at the east side of the building: Employees were working on a 6-story-high supported scaffold, and climbed the frames and cross braces of the scaffold as a means of access. On or about 06/09/17.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2017-11-16
Current Penalty 3803.0
Initial Penalty 3803.0
Final Order 2018-02-27
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. a) 6-story high supported scaffold at the east side of the building: Employees were working on a 6-story-high supported scaffold, and were not protected from falling to lower levels by the use of fall protection systems. Employees were exposed to falling approximately 60 feet. On or about 06/09/17.

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
2912335 Intrastate Non-Hazmat 2016-07-26 - - 2 2 Private(Property)
Legal Name CAPTAIN BUILDERS INC
DBA Name -
Physical Address 5802 AVENUE N , BROOKLYN, NY, 11234-4128, US
Mailing Address 5802 AVENUE N , BROOKLYN, NY, 11234-4128, US
Phone (718) 314-3671
Fax -
E-mail CATTOM3@AOL.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 25 Mar 2025

Sources: New York Secretary of State