Search icon

ARIEL CONSTRUCTION INC.

Company Details

Name: ARIEL CONSTRUCTION INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 19 Nov 2015 (9 years ago)
Entity Number: 4852252
ZIP code: 11516
County: Nassau
Place of Formation: New York
Address: 434 BAYVIEW AVE, 1 FLOOR, CEDARHURST, NY, United States, 11516

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 434 BAYVIEW AVE, 1 FLOOR, CEDARHURST, NY, United States, 11516

Filings

Filing Number Date Filed Type Effective Date
151119010049 2015-11-19 CERTIFICATE OF INCORPORATION 2015-11-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343409611 0215000 2018-08-22 1255 BUSHWICH AVENUE, BROOKLYN, NY, 11207
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2018-08-22
Case Closed 2018-08-28

Related Activity

Type Inspection
Activity Nr 1257729
Safety Yes
342577293 0215000 2017-08-19 1255 BUSHWICK AVENUE, BROOKLYN, NY, 11207
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2017-08-19
Emphasis L: LOCALTARG, P: LOCALTARG
Case Closed 2022-01-06

Related Activity

Type Inspection
Activity Nr 1257634
Safety Yes
Type Inspection
Activity Nr 1257723
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2017-11-02
Abatement Due Date 2017-11-08
Current Penalty 5070.0
Initial Penalty 5070.0
Final Order 2018-02-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Location: a) Supported scaffold on the roof of the jobsite: On or about 08/19/17, employees were doing stucco work on the roof from a single-tier-high supported scaffold that was not fully planked or decked between front upright and the guardrail supports, and were exposed to falling approximately 15 feet to the lower level.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2017-11-02
Abatement Due Date 2017-11-13
Current Penalty 2897.0
Initial Penalty 2897.0
Final Order 2018-02-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Location: a) Supported scaffold on the roof of the jobsite: On or about 08/19/17, employees climbed the crossbraces and frame as a mean of access from the roof to the first tier platform of a single-tier-high supported scaffold.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2017-11-02
Abatement Due Date 2017-11-08
Current Penalty 5070.0
Initial Penalty 5070.0
Final Order 2018-02-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: a) Supported scaffold on the roof of the jobsite On or about 08/19/17, employees were doing stucco work on the roof from a single-tier-high supported scaffold, and were not protected from falling approximately 15 feet to a lower level.

Date of last update: 25 Mar 2025