346311574
|
0213600
|
2022-10-28
|
595 LINCOLN AVENUE, LOCKPORT, NY, 14094
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-10-28
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2024-12-31
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2022-11-17 |
Current Penalty |
1500.0 |
Initial Penalty |
3522.0 |
Contest Date |
2023-05-04 |
Final Order |
2023-07-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 10/28/2022, employee was exposed to a fall hazard by not utilizing fall protection while working from a ladder jack scaffold which was elevated 17 feet from ground level. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2022-11-17 |
Current Penalty |
1500.0 |
Initial Penalty |
3522.0 |
Contest Date |
2023-05-04 |
Final Order |
2023-07-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 10/28/2022 at a residential home roofing site located at 595 Lincoln Ave, Lockport NY; employees, without fall protection, were working on a two-story building roof. Employees were installing shingles on the roof of a gable end at a height of approximately 25 feet. There were no fall protection measures in place. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2022-11-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2023-05-04 |
Final Order |
2023-12-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10):"Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. a) On or about 10/26/2022, at a residential roof located at 595 Lincoln Ave. Lockport, NY; the employer did not enforce the use of fall protection for employees installing shingles 12 ft above lower levels. The employer allowed employees to work on elevated surfaces greater than 6 feet high without fall protection. NO ABATEMENT CERITIFICATION REQUIRED |
|
|
342600855
|
0213600
|
2017-08-28
|
2974 LOCKPORT-OLCOTT ROAD, NEWFANE, NY, 14108
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-08-28
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2019-11-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2017-09-21 |
Current Penalty |
1000.0 |
Initial Penalty |
2897.0 |
Final Order |
2017-10-04 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 08/28/17, on jobsite at a house at 2974 Lockport Olcott Rd., Newfane , NY: Employees were exposed to a potential fall of approx. 17 ft. from the pik on a Ladder Jack Scaffold erected on the right side of the house while standing on the pik engaged in roof tear-off work. No Fall protection system was being utilized. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2017-09-21 |
Current Penalty |
2450.0 |
Initial Penalty |
3622.0 |
Final Order |
2017-10-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 08/28/17, on the upper roof of a house at 2974 Lockport Olcott Rd., Newfane, NY: Five employees engaged in roofing tear-off work on a steep roof on the right side of the house were exposed to a fall of approx. 20 foot. No fall protection system was being utilized. Pitch of the roof was approx. 8 in 12. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2017-09-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-10-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system alone: a) On or about 08/28/17, on the low slope porch roof of a house at 2974 Lockport Olcott Rd., Newfane , NY: Two employees engaged in roofing work were exposed to a fall of approx. 12 ft. No fall protection system was utilized on this roof. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2017-09-21 |
Current Penalty |
1000.0 |
Initial Penalty |
2173.0 |
Final Order |
2017-10-04 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) On or about 08/28/17, on the front side of a house at 2974 Lockport Olcott Rd., Newfane , NY: Employees used an extension ladder to access the porch roof from the ground. The side rails of that ladder only extended approx. 12 inches above the roof. b) On or about 08/28/17, on the front side of a house at 2974 Lockport Olcott Rd., Newfane , NY: An employee used the support ladder of a Ladder Jack Scaffold erected on the porch roof to exit the upper roof onto the scaffold pik. The side rails of that support ladder only reached to the bottom of the gutter which was below the roof edge. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
342504636
|
0213600
|
2017-07-25
|
74 AVIAN WAY, LANCASTER, NY, 14086
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-07-25
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2019-11-13
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2017-09-28 |
Current Penalty |
1000.0 |
Initial Penalty |
1847.0 |
Final Order |
2017-10-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 7/25/17 at a roof replacement project located at 74 Avian Way, Lancaster, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2017-09-28 |
Current Penalty |
1500.0 |
Initial Penalty |
3078.0 |
Final Order |
2017-10-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: a) On or about 7/25/17 at a roof replacement project located at 74 Avian Way, Lancaster, New York; employees were using a ladder jack scaffold, with the scaffold brackets and platform to the outside of the supporting ladders. The employees had to access the platform by climbing the supporting ladders and climbing around the bracket and platform. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2017-09-28 |
Current Penalty |
1500.0 |
Initial Penalty |
3078.0 |
Final Order |
2017-10-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 7/25/17 at a roof replacement project located at 74 Avian Way, Lancaster, New York; employees performing roofing activities from a ladder jack scaffold approximately 16 feet high and were not protected from falling by a personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2017-09-28 |
Current Penalty |
1550.0 |
Initial Penalty |
3078.0 |
Final Order |
2017-10-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 7/25/17 at a roof replacement project located at 74 Avian Way, Lancaster, New York; employees working on the roof were placing shingles on the roof of a two story house. The roof had a 6 in 12 pitch and an eave heights of approximately 18 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED |
|
|