Search icon

PERINI GROUP, INC

Company Details

Name: PERINI GROUP, INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 02 Dec 2015 (9 years ago)
Entity Number: 4857890
ZIP code: 10018
County: New York
Place of Formation: New York
Address: 400 5TH AVENUE, 49F, NEW YORK, NY, United States, 10018

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
PERINI GROUP, INC DOS Process Agent 400 5TH AVENUE, 49F, NEW YORK, NY, United States, 10018

History

Start date End date Type Value
2023-03-23 2024-12-18 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-05-03 2023-03-23 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-04-01 2022-05-03 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-03-21 2022-04-01 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2021-10-07 2022-03-21 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2015-12-02 2021-10-07 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
151202010302 2015-12-02 CERTIFICATE OF INCORPORATION 2015-12-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343731311 0215600 2019-01-11 112-51 NORTHERN BLVD, FLUSHING, NY, 11368
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2019-01-11
Emphasis N: TRENCH

Related Activity

Type Referral
Activity Nr 1419311
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260652 A01
Issuance Date 2019-06-04
Current Penalty 2500.0
Initial Penalty 5834.0
Contest Date 2019-06-20
Final Order 2020-04-10
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c) A). On or about 1/04/2019, at wall adjacent to westbound lane, 112-51 Northern Blvd. Corona, NY Employees working in approximately 40 ft. deep a triangle shaped excavation with sides measuring approximately 310 ft. x 360 ft. x 480 ft. were in danger of a partial wall collapse due to insufficient support. Employer did not ensure that all tie backs installed on soil nail wall were consistent with the engineering plan. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 02001
Citaton Type Other
Standard Cited 19040040 A
Issuance Date 2019-06-04
Abatement Due Date 2019-06-21
Current Penalty 500.0
Initial Penalty 834.0
Contest Date 2019-06-20
Final Order 2020-04-10
Nr Instances 1
Nr Exposed 23
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. A). On or about 1 4, 2019: at Job site at 112-51 Northern Blvd. Corona, NY CSHO requested copies of OSHA 300 Logs on May 8, 2019, OSHA 300 Logs were not provided to CSHO. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
342073889 0215600 2017-01-27 42-31 UNION STREET, FLUSHING, NY, 11355
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2017-01-27
Emphasis L: FALL
Case Closed 2018-03-30

Related Activity

Type Referral
Activity Nr 1179195
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260502 I02
Issuance Date 2017-07-26
Abatement Due Date 2017-08-01
Current Penalty 2535.0
Initial Penalty 5070.0
Contest Date 2017-08-17
Final Order 2017-12-27
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(2): Covers were not capable of supporting, without failure, at least twice the weight of employees, equipment, and materials that may be imposed on the cover at any one time: On or about January 27, 2017 - 18th Floor at 42-31 Union Street, Flushing, NY 11355. Employees glazing windows on 18th floor in which the floor hole cover was worn, water damaged and did not support the weight of materials or employees. WRITTEN ABATEMENT VERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260502 I03
Issuance Date 2017-07-26
Abatement Due Date 2017-07-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2017-08-17
Final Order 2017-12-27
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: On or about January 27, 2017 - 18th Floor at 42-31 Union Street, Flushing, NY 11355. Employees glazing windows on 18th floor in which floor hole cover was not secured to prevent displacement. WRITTEN ABATEMENT VERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260502 I04
Issuance Date 2017-07-26
Abatement Due Date 2017-07-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2017-08-17
Final Order 2017-12-27
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(4): Covers for holes in floors, roofs, and other walking/working surfaces were not color coded or marked with the word "HOLE" or "COVER" to provide adequate warning of the hazard: On or about January 27, 2017 - 18 Floor at 42-31 Union Street, Flushing, NY 11355. Employees glazing windows on the 18th floor in which the floor hole covered with wood was not marked. WRITTEN ABATEMENT VERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.

Date of last update: 25 Mar 2025