348006495
|
0214700
|
2025-01-28
|
44 DEPOT ROAD, WESTHAMPTON, NY, 11977
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2025-01-28
|
Emphasis |
N: FALL
|
Related Activity
Type |
Inspection |
Activity Nr |
1800662 |
Safety |
Yes |
|
|
344087242
|
0214700
|
2019-06-12
|
1661 WILLIAM FLOYD PARKWAY, YAPHANK, NY, 11980
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-06-12
|
Emphasis |
L: FALL, N: AMPUTATE
|
Case Closed |
2024-09-30
|
Related Activity
Type |
Inspection |
Activity Nr |
1408914 |
Safety |
Yes |
|
Type |
Referral |
Activity Nr |
1466207 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1408907 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2019-12-11 |
Abatement Due Date |
2019-12-23 |
Current Penalty |
3500.0 |
Initial Penalty |
5834.0 |
Contest Date |
2019-12-18 |
Final Order |
2020-06-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to employees in that employees were exposed to amputation/caught-in hazards while operating a Makita 5007F circular saw: a) Worksite: Employees were operating a Makita 5007F circular saw with one hand on the equipment and one hand on the workpiece. Employees were to exposed to amputation and caught in hazards; on or about 6/11/19. Note: In addition to abatement certification, the employer is required to provide abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
|
343853198
|
0214700
|
2019-03-08
|
857 S. OYSTER BAY ROAD, BETHPAGE, NY, 11714
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-03-08
|
Emphasis |
L: FALL
|
Case Closed |
2019-09-04
|
Related Activity
Type |
Inspection |
Activity Nr |
1384028 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1385316 |
Safety |
Yes |
|
|
343654679
|
0214700
|
2018-12-11
|
1155 MONTAUK HIGHWAY, EAST PATCHOGUE, NY, 11772
|
|
Inspection Type |
Fat/Cat
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-01-16
|
Emphasis |
L: FALL, N: SVEP
|
Related Activity
Type |
Accident |
Activity Nr |
1408265 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2019-06-05 |
Abatement Due Date |
2019-06-11 |
Current Penalty |
6126.0 |
Initial Penalty |
10210.0 |
Contest Date |
2019-06-06 |
Final Order |
2024-05-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, 1155 Montauk Highway, East Patchogue, NY: Employees assembling a shed where there was possible danger of head injury from impact of falling/flying objects such as tools, metal roof panels, and trusses were not protected by protective helmets; on or about 12/8/18. NOTE: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2019-06-05 |
Abatement Due Date |
2019-06-11 |
Current Penalty |
6126.0 |
Initial Penalty |
10210.0 |
Contest Date |
2019-06-06 |
Final Order |
2024-05-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed. a) Worksite, 1155 Montauk Highway, East Patchogue. NY: An employee was using a blue A-frame ladder in the closed position to access the top of a storage container; on or about 12/8/18. NOTE: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2019-06-05 |
Abatement Due Date |
2019-06-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2019-06-06 |
Final Order |
2024-05-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Worksite, 1155 Montauk Highway, East Patchogue. NY: Employees were using the top step of a blue A-frame ladder to access the top of a storage container; on or about 12/8/18. NOTE: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19 |
|
Citation ID |
02001 |
Citaton Type |
Willful |
Standard Cited |
19260501 A02 |
Issuance Date |
2019-06-05 |
Abatement Due Date |
2019-06-11 |
Current Penalty |
65874.0 |
Initial Penalty |
102100.0 |
Contest Date |
2019-06-06 |
Final Order |
2024-05-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(a)(2): Employees were allowed to work on surfaces which did not have the requisite strength and structural integrity: a) Worksite, 1155 Montauk Highway, East Patchogue. NY: An employee assisting with the assembly of a shed in the rear yard of the worksite was exposed to fall hazards while walking on the roof panels of the partially completed structure, approximately 12ft above the concrete surface below; on or about 12/8/2018. NOTE: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance to 29 CFR 1903.19. |
|
Citation ID |
02002A |
Citaton Type |
Willful |
Standard Cited |
19260501 B01 |
Issuance Date |
2019-06-05 |
Abatement Due Date |
2019-06-11 |
Current Penalty |
65874.0 |
Initial Penalty |
102100.0 |
Contest Date |
2019-06-06 |
Final Order |
2024-05-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. Worksite, 1155 Montauk Highway, East Patchogue. NY: Employees, assigned to assemble a shed in the rear yard of the building, were working from the top of a storage container, approximately 7 ft. above ground without being protected by the use of guardrail systems, safety net systems, or personal fall arrest systems; on or about 12/8/18. NOTE: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance to 29 CFR 1903.19. |
|
Citation ID |
02002B |
Citaton Type |
Willful |
Standard Cited |
19260501 B02 I |
Issuance Date |
2019-06-05 |
Abatement Due Date |
2019-06-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2019-06-06 |
Final Order |
2024-05-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(2)(i): Each employee who was constructing a leading edge 6 feet or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems: Note: If the employer could demonstrate that it was infeasible or created a greater hazard to use these systems, a fall protection plan meeting the requirements of paragraph (k) of 1926.502 should have been developed and implemented. a. Worksite, 1155 Montauk Highway, East Patchogue. NY: An employee assigned to assemble a shed in the rear yard of the building was constructing a leading edge of the metal roof panels approximately 12 ft. above ground without being protected by the use of guardrail systems, safety net systems, or personal fall arrest systems; on or about 12/8/18. NOTE: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance to 29 CFR 1903.19. |
|
|
342650900
|
0214700
|
2017-08-09
|
1427 OLD COUNTRY ROAD, PLAINVIEW, NY, 11803
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-08-09
|
Emphasis |
L: FALL, L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2023-04-04
|
Related Activity
Type |
Inspection |
Activity Nr |
1253492 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1253577 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1253519 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1254116 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1253532 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1254124 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1254136 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1253555 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2018-01-19 |
Current Penalty |
0.0 |
Initial Penalty |
2217.0 |
Contest Date |
2018-04-17 |
Final Order |
2018-08-09 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Worksite: Employees conducting framing activities using pneumatic nail guns were not wearing eye protection; on or about 8/9/17. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260502 K01 |
Issuance Date |
2018-01-19 |
Current Penalty |
5172.0 |
Initial Penalty |
5174.0 |
Contest Date |
2018-04-17 |
Final Order |
2018-08-09 |
Nr Instances |
3 |
Nr Exposed |
11 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
1926.502(k)(1): The fall protection plan shall be prepared by a qualified person and developed specifically for the site where the leading edge work, precast concrete work, or residential construction work is being performed and the plan must be maintained up to date. a) Worksite, Building 34: Employees who were framing the residential construction without fall protection were exposed to falls of up to and including approximately 12 ft. to the ground below; on or about 8/9/17. b) Worksite, Building 39: Employees who were framing the residential construction without fall protection were exposed to falls of up to and including approximately 12 ft. to the ground below; on or about 8/9/17. c) Worksite, Building 48: Employees who were framing the residential construction without fall protection were exposed to falls of up to and including approximately 12 ft. to the ground below; on or about 8/9/17. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19261053 B01 |
Issuance Date |
2018-01-19 |
Current Penalty |
0.0 |
Initial Penalty |
3696.0 |
Contest Date |
2018-04-17 |
Final Order |
2018-08-09 |
Nr Instances |
2 |
Nr Exposed |
9 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder length allows, the ladder side rails did not extend at least 3 feet (36 in.) above the upper landing surface being accessed: a) Worksite, Building #39: Employees were accessing a landing approximately 12 ft. above the ground. The portable extension ladder used to access the surface extended approximately 18 in. above the landing surface; on or about 8/9/17. b) Worksite, Building #48:Employees were accessing a landing approximately 12 ft. above the ground. The portable extension ladder used to access the surface extended approximately 18 in. above the landing surface; on or about 8/9/17. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
|
300136355
|
0214700
|
1997-12-03
|
128 SHEPERD STREET, ROCKVILLE CENTRE, NY, 11570
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1997-12-03
|
Case Closed |