Name: | JA NEW GENERATION CONSTRUCTION CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 07 Jan 2016 (9 years ago) |
Entity Number: | 4874187 |
ZIP code: | 11550 |
County: | Nassau |
Place of Formation: | New York |
Address: | 114 BEVERLY RD, HEMPSTEAD, NY, United States, 11550 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
JOSE E. ARITA CEBALLOS | DOS Process Agent | 114 BEVERLY RD, HEMPSTEAD, NY, United States, 11550 |
Start date | End date | Type | Value |
---|---|---|---|
2016-01-07 | 2024-04-05 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
160107010113 | 2016-01-07 | CERTIFICATE OF INCORPORATION | 2016-01-07 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345308928 | 0215000 | 2021-05-13 | 1134 EAST 9TH STREET, BROOKLYN, NY, 11230 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1530890 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19261052 C01 I |
Issuance Date | 2021-11-04 |
Abatement Due Date | 2021-11-17 |
Current Penalty | 1230.0 |
Initial Penalty | 1931.0 |
Final Order | 2021-12-07 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(1)(i):Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: Location: 1134 East 9th Street, Brooklyn, NY 11230 On or about: May 13, 2021 (a) Employee(s) were exposed to a fall hazard while accessing the first floor interior from the front entrance; the stairway was not equipped with at least one handrail. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2021-11-04 |
Abatement Due Date | 2021-11-17 |
Current Penalty | 2070.0 |
Initial Penalty | 3218.0 |
Final Order | 2021-12-07 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed: Location: 1134 East 9th Street, Brooklyn, NY 11230 On or about: May 13, 2021 (a) Employee(s) used an A-frame ladder as a extension ladder. The ladder was in a folded position and used to access a scaffold. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2016-07-27 |
Case Closed | 2017-03-03 |
Related Activity
Type | Referral |
Activity Nr | 1117993 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260404 F06 |
Issuance Date | 2016-12-20 |
Abatement Due Date | 2016-12-29 |
Current Penalty | 1750.0 |
Initial Penalty | 2672.0 |
Final Order | 2017-01-30 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Pump Jack Scaffold: On or about July 27, 2016 An employee used a DeWalt mixer which was plugged in by extension cord. The extension cord was missing the ground pin. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G04 I |
Issuance Date | 2016-12-20 |
Abatement Due Date | 2016-12-29 |
Current Penalty | 2600.0 |
Initial Penalty | 3741.0 |
Final Order | 2017-01-30 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. a) Pump Jack Scaffold: On or about July 27, 2016 The pump jack scaffold was not guarded on the end and the laborer was exposed to falls of 23 feet. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261051 A |
Issuance Date | 2016-12-20 |
Abatement Due Date | 2016-12-29 |
Current Penalty | 1400.0 |
Initial Penalty | 2138.0 |
Final Order | 2017-01-30 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1051(a): A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. a) Pump Jack Scaffold: On or about July 27, 2016 The access to the pump jack scaffold was a scaffold plank which bridged across an break in elevation of 46 inches. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9305837303 | 2020-05-01 | 0235 | PPP | 3831 Waverly Ave, Seaford, NY, 11783 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
8725738502 | 2021-03-10 | 0235 | PPS | 3831 Waverly Ave, Seaford, NY, 11783-2612 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2914550 | Intrastate Non-Hazmat | 2016-08-02 | - | - | 3 | 3 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Date of last update: 25 Mar 2025
Sources: New York Secretary of State