Name: | MESA PAINTING CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 08 Jan 2016 (9 years ago) |
Entity Number: | 4875864 |
ZIP code: | 11214 |
County: | Kings |
Place of Formation: | New York |
Address: | 7815 17TH AVENUE, FLOOR 2, BROOKLYN, NY, United States, 11214 |
Shares Details
Shares issued 20000
Share Par Value 1
Type PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 7815 17TH AVENUE, FLOOR 2, BROOKLYN, NY, United States, 11214 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
160108010402 | 2016-01-08 | CERTIFICATE OF INCORPORATION | 2016-01-08 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344401484 | 0215000 | 2019-10-24 | 1325 53RD STREET, BROOKLYN, NY, 11219 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260405 G02 III |
Issuance Date | 2020-03-20 |
Current Penalty | 3470.0 |
Initial Penalty | 3470.0 |
Final Order | 2020-04-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap. Location: 1325 53rd Street, Brooklyn, NY; 2nd floor On or about 10/24/2019, a) Employees used a work light that was spliced to a flexible cord. The spliced was covered with electrical tape. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260416 E01 |
Issuance Date | 2020-03-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2020-04-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used. Location: 1325 53rd Street, Brooklyn, NY; 2nd floor On or about 10/24/2019, a) The electrical cord of the work light used by employees was frayed and it was covered by electrical tape. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19260404 F06 |
Issuance Date | 2020-03-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2020-04-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. Location: 1325 53rd Street, Brooklyn, NY; 2nd floor On or about 10/24/2019, a) The ground pin at the cord of the work light used by employees was missing. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B16 |
Issuance Date | 2020-03-20 |
Current Penalty | 2313.0 |
Initial Penalty | 2313.0 |
Final Order | 2020-04-20 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. Location: 1325 53rd Street, Brooklyn, NY; 2nd floor On or about 10/24/2019, a) A portable ladder with broken component was not removed from service. Employees used a 4 feet portable ladder with a broken rear horizontal brace. |